Charging The Accumulator - Stanley GD50 User Manual

Hydraulic ground rod driver
Hide thumbs Also See for GD50:
Table of Contents

Advertisement

To check or charge the accumulator the following
equipment is required:
Charge kit (Part Number 31254) Includes the
following:
Accumulator tester (P/N 02835).
Charge assembly (P/N 15304). Includes a liquid-
filled gauge with snub valve, hose and fittings.
NITROGEN bottle with a 800 psi/56 bar minimum
charge (not a part of 31254 kit).
1. Holding the chuck end of the STANLEY tester
(P/N 02835), turn the gauge fully counterclockwise
to ensure the stem inside the chuck is completely
retracted.
Charging the Accumulator (BR72125S & BR72135S)
2. Thread the tester onto the charging valve of the tool
accumulator (do not advance the gauge-end into
the chuck end. Turn as a unit). Seat the chuck on
the accumulator charging valve by hand tightening
CW
only.
3. Advance the valve stem by turning the gauge-end
clockwise.
4. Connect the charging assembly to the valve on the
tester.
GAUGE
5. Adjust the regulator on the nitrogen bottle to 600
psi/42 bar.
Note: It may be necessary to set the regulator at
650–700 psi/41–48 bar to overcome any pressure
ACCUMULATOR TESTER ( P/ N 02835 )
drop through the charging system.
31254 ACCUMULATOR CHARGE KIT
31254 ACCUMULATOR CHARGE KIT
Includes: Liquid Filled Gauge w/Snub Valve,
Includes: Liquid Filled Gauge w/ Snub Valve,
Hose, Charge Fitting, 02835 Tester, and Box
Hose, Charge Fitting, 02835 Tester, and Box
(not pictured)
(not pictured)
Charging the Accumulator (BR72120 & B 72130)
12 ► GD50 User Manual
CW

CHARGING THE ACCUMULATOR

TESTER CHARGING
VALVE
CHUCK
Liquid Filled Gauge w/Snub Valve
Liquid Filled Gauge w/ Snub Valve
Figure 3. Charging the Accumulator
TESTER CHARGING
VALVE
6. Open the valve on the charging assembly hose.
When the tester gauge reads 600–700 psi/41–48
bar, close the valve on the charging assembly hose
and remove the charging assembly.
7. Turn the gauge end of the tester fully
counterclockwise to retract the plunger in the
chuck. Remove the tester from the charge valve.
8. Replace the valve cap.
TESTING THE ACCUMULATOR
PRESSURE
1. Follow Steps 1 through 3 under CHARGING THE
ACCUMULATOR.
2. Read the pressure on the gauge. It should be
between 500–700 psi/35–48 bar.
3. If the pressure is low, recharge the tool.
LOCATION OF CHARGING VALVE
Figure 2
Nitrogen Tank
Nitrogen Tank
(
)
(Not included in Kit)
Not included in Kit
Hose
Hose
Gauge
Gauge
Chuck
R
Charge Fitting
Charge Fitting
Charging Valve
Charging Valve
02835 TESTER
02835 Tester
Chuck

Advertisement

Table of Contents
loading