CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined
A
areas, extra care should be exercised when lighting propane heaters.
A.
This appliance is equipped with an ignition
device which automatically lights the pilot. Do
not try to light the pilot by hand.
B.
BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell near
the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
*Do not try to light any appliance.
*Do not touch any electric switch; do not use
any phone in your building.
*Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
1.
STOP! Read the safety information above.
2.
Set the thermostat to the lowest setting.
3.
Turn off all electrical power to the appliance.
4.
This appliance is equipped with an ignition
device which automatically lights the pilot. Do
not try to light the pilot by hand.
5.
Remove heater door panel.
6.
Turn gas control knob clockwise
"Off". (Honeywell VR 8300 and Robertshaw
7000)
7.
Wait 5 minutes to clear out any gas. If you
then smell gas, STOP! Follow "B in the safety
information above. If you don't smell gas, go
to the next step.
8.
Turn gas control knob counter-clockwise
to "On". (Honeywell VR 8300 and Robertshaw
7000)
9.
Replace heater door panel.
10. Turn on all electrical power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the
instructions "To Turn Off Gas To Appliance"
and call your service technician or gas
supplier.
1. Set the thermostat at the lowest setting.
2. Turn off all the electrical power to the appli-
ance if service is to be performed.
3. Remove heater door panel.
OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES
ELECTRONIC IGNITION SYSTEM
(AUTOMATICALLY LIGHTED PILOT)
OPERATING INSTRUCTIONS
SHUT-OFF PROCEDURES
*If you cannot reach your gas supplier, call the
fire department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob
will not push in or turn by hand, do not try to
repair it. Call a qualified service technician.
Force or attempted repair may result in a fire
or explosion.
D.
Do not use this appliance if any part has been
under water. Immediately call a qualified
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
water.
HONEYWELL
VR 8300 GAS
VALVE IID
GAS
INLET
to
ROBERTSHAW 7000
GAS VALVE IID
4. For Honeywell VR 8300 and Robertshaw
7000 gas valve.
Turn gas control knob clockwise
to "Off". Make sure knob rest against stop.
5. Replace heater door panel.