Replacement Parts - Raypak 408 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

8.5.17. Unitherm Governor Replacement
1. Shut water, gas and electricity off, close valves and
relieve pressure.
2. Drain heat exchanger.
3. Remove retainer plug located next to the outlet pipe
connection.
4. Unsnap old unitherm governor to remove from
retainer plug. Snap in new unitherm governor.
5. Reinstall retainer plug, taking care to lubricate
gasket with a non-petroleum based grease such as
AquaLube.
UG PLUG
Figure 53. Unitherm Governor Valve
To test the operation of the Unitherm Governor, place in
hot water (over 110°F [43°C]) and watch for movement
against spring. If there is no movement, replace unit.
32
GASKET
(BEHIND UG)
UNITHERM
GOVERNOR
UG SPRING

9. REPLACEMENT PARTS

NOTE: To supply you with the correct part, it is important
that you supply the heater model number, serial number
and type of gas when applicable.
Any part returned for replacement under standard
company warranties must be properly tagged with a
return parts tag, completely filled in with the heater serial
number, model number, etc., and shipped to the Company
freight prepaid. If determined defective by the Company
and within warranty, a like part or equal substitution will
be returned, freight collect. Credit will not be issued.
MANUFACTURER:
2151 Eastman Avenue
Oxnard, Ca 93030

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

268

Table of Contents