Troubleshooting - Dometic PR2000 Operating Manual

Awnings perfectroof
Hide thumbs Also See for PR2000:
Table of Contents

Advertisement

PR2000_PR2500-O-16S.book Seite 24 Donnerstag, 5. Oktober 2017 10:23 10

Troubleshooting

➤ Lift up the front panel slightly so that the hinge does not bear any load.
➤ Tighten the screws with 15 – 25 Nm.
8.5
Patching small holes in the fabric
You can patch any small holes in the fabric or parts where the coating has come off:
➤ Use a cotton cloth to rub around the damaged area with a small amount of liquid
vinyl plaster (ref. no. 9103104018, available from your service partner).
✓ The liquid vinyl plaster dissolves the coating. The coating seals the hole when it
dries.
➤ Wait until the area is dry before you retract the awning again.
9
Troubleshooting
I
NOTE
If you are not able to rectify a fault with the help of the following table,
please contact the relevant service partner in your country (see the back
of the manual for the address).
Fault
PR2500 only:
The motor is not
responding to the
remote control.
24
Possible cause
The remote control
battery is flat.
The remote control is no
longer or not properly
set to the motor.
No power supply
available
The motor is defective.
Suggested remedy
Briefly press one of the buttons
. If the remote control LED does not
light up, the battery is flat.
Replace the battery, see chapter
"Replacing the batteries of the remote
control and the wall switch (only
PR2500, optional)" on page 22.
Reprogram the remote control, see the
installation manual.
Check the electric connections.
Retract the awning manually and
contact the service partner in the
respective country.
PR2000, PR2500
or
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr2500

Table of Contents