Download Print this page

Pentair DigiTrace RTD50CS Installation Instructions

Rtd temperature sensor for temperature measurement to 400f (204c)

Advertisement

Quick Links

RTD TEMPERATURE SENSOR FOR TEMPERATURE MEASUREMENT TO 400°F (204°C)

INSTALLATION INSTRUCTIONS

APPROVALS
SPECIFICATIONS
Sensor
Housing
316 stainless steel
Dimensions
Sensing area
Accuracy
Range
Resistance
WARNING:
This component is an electrical device. It must be installed
correctly to ensure proper operation and to prevent shock or
fire. Read these important warnings and carefully follow all the
THERMAL MANAGEMENT SOLUTIONS
RTD50CS
α
installation instructions. Component approvals and performance
are based on the use of s pecified parts only. Do not use substitute
parts or vinyl electrical tape to make connections.
EN-DigiTraceRTD50CS-IM-H58856      01/13
DESCRIPTION
The RTD50CS is a 50-foot three-wire platinum RTD (resistance
temperature detector) used with monitoring and control systems,
such as our DigiTrace C910 or ACCS-30 controllers.
The RTD50CS can be installed directly to the controller using the
supplied 1/2-inch conduit fitting or to an RTD junction box where
RTD extension wire is used.
TOOLS REQUIRED
ADDITIONAL MATERIALS REQUIRED
KIT CONTENTS
Qty
Description
1
RTD temperature sensor
Extension Wires
Wire size
20 AWG, stranded tinned copper
(each of 3)
Wire insulation
rating
Length
lead wire
Outer shield
Stainless steel flexible armor
Maximum exposure
temperature
Conduit bushing
½ in NPT
1 / 2

Advertisement

loading

Summary of Contents for Pentair DigiTrace RTD50CS

  • Page 1: Installation Instructions

    RTD50CS RTD TEMPERATURE SENSOR FOR TEMPERATURE MEASUREMENT TO 400°F (204°C) INSTALLATION INSTRUCTIONS DESCRIPTION The RTD50CS is a 50-foot three-wire platinum RTD (resistance temperature detector) used with monitoring and control systems, such as our DigiTrace C910 or ACCS-30 controllers. The RTD50CS can be installed directly to the controller using the supplied 1/2-inch conduit fitting or to an RTD junction box where RTD extension wire is used.
  • Page 2 Fax: +1.650.474.7711 thermal.info@pentair.com Pentair and DigiTrace are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. © 2012-2013 Pentair. PN P000001512 EN-DigiTraceRTD50CS-IM-H58856      01/13...