Electrical And Plumbing - Fisher & Paykel ACTIVESMART RS90A Installation Manual

Integrated slide-in refrigerator
Hide thumbs Also See for ACTIVESMART RS90A:
Table of Contents

Advertisement

WARNING!
Electrical shock hazard. Assume all parts are live.
Disconnect supply before servicing and installation.
Left side
of cavity
!
Optional electrical and
water connection location*
Floor
145mm
REAR VIEW OF CAVITY
Note: We recommend to use an isolating switch that is easily
accessible to the user after the refrigerator is installed.
ELECTRICAL SPECIFICATIONS
Supply
Service
PLUMBING SPECIFICATIONS
Supply
Pressure
Note: recommended that the electrical & water connection be located in an adjacent cabinet to either side of the fridge or above
the fridge cavity.
Do not locate water or electricity in this area, keep clear of connections.
!
CAUTION: Central area can only fit water outlet and electrical plug if they are placed within a recessed cavity.
!
* In this location the water tap needs to be recessed into the wall, the recess must allow for an 80mm bend radius for the water tube.
10
7

 ELECTRICAL AND PLUMBING

100mm
130mm
100mm
72mm
355mm
REAR VIEW OF CAVITY
RS90A
230 VAC, 50 Hz
10 amp circuit
½" BSP threaded water connection
Maximum 120 psi (827 kPa) @ 20°C
RS90AU
230 VAC, 50 Hz
10 amp circuit
6.35mm PEX tubing
Minimum 22 psi (150 kPa)
Alternative area above
cavity for connections
Electrical
Plumbing
Electrical
Plumbing