Starting Up The Boiler - Potterton SIRIUS THREE FS 50 Installation Manual

Floor-standing condensing gas boiler
Table of Contents

Advertisement

8.2

Starting up the boiler

Fig.74
Putting the boiler into operation
1
8.3
Stopping the boiler
8.4
Frost Protection
7609493 - v08 - 24072018
1. Start up the boiler by pressing the ON/OFF switch.
2. Open the gas cock.
3. Press the
4. Select the Standby/operation parameter by turning the
5. Press the
The
MW-3000050
Important
Choose the operating mode Off or Standby.
1. Switch off the boiler by pressing the ON/OFF switch.
2. Close the gas cock.
8.3.1
1. Press the
2. Select the Standby/operation parameter by turning the
3. Press the
The
The electronic management system of the boiler includes protection
against frost. If the water temperature falls below 5°C, the burner starts up
in order to provide a water temperature of 30°C.
This function only works if the boiler is turned on, the gas supply open and
the hydraulic pressure correct.
8.4.1
1. Press the
2. Select the parameter Central heating mode CH1 by turning the
button.
3. Confirm the selection by pressing the
4. Select the parameter Off by turning the
5. Confirm the selection by pressing the
The
key to access the shortcuts menu.
button to start up the boiler.
symbol disappears.
Putting the boiler in Standby mode
key to access the shortcuts menu.
button to put the boiler in standby.
symbol is displayed.
Activating the Off
key to access the shortcuts menu.
symbol is displayed.
Important
When the operating mode Off is activated:
The electrical circuits continue to be powered up.
The frost protection function is activated.
8 Operation
button.
button.
button.
button.
button.
69