Receiver Wiring (RF models only)
GB
RX1
ELECTRONICS
N L
Note:
1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.
Commissioning (RF versions only)
If the thermostat and the receiver have been supplied together in
a combined pack, the units have been paired in the factory and no
commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow
steps 1-5 below.
1. TP7000-RF
Press the recessed RESET button, using a non-
metallic object, to reset the unit.
2. Press & hold the recessed LEARN button for 3
seconds, using a non-metallic object.
NOTE: Thermostat now transmits continuously for 5 mins.
3. RX1 - Press and hold buttons PROG and CH1 for
3 seconds until green light fl ashes once.
4. RX2 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps1-2 and then press PROG and CH2
on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1 – 3.
Stat 2 - wait 5 mins, perform steps 1-2 and then press PROG and CH2
on RX3.
Stat 3 - wait 5 mins, perform steps 1-2 and then press PROG and CH3
on RX3.
5. TP7000-RF - Press
normal operation.
6
1 2 3 4
COM
ZONE
ZONE
1 OFF
1 ON
or
to return the unit to
RX2 & RX3
ELECTRONICS
A
B C 1 2 3 4 5 6
N
L
COM
TERMINAL 6
RX3 ONLY
ZONE
ZONE
ZONE
ZONE
1 ON
1 OFF
2 ON
3 ON
RESET
LEARN