6 O
P
UTPUT
ERFORMANCE
Please refer to the test results supplied with the unit for its unique performance.
Typical performance results are shown in the sections below.
6.1 Flicker Load Operation
The typical flicker disturbance generated by the HFG02 in each of the steady flicker
modes when tested according to EN/IEC 61000-3-3 is shown in Table 3.
Flicker Mode
Load Operation
Setting
8.3/8.6 Hz
8.33 Hz flicker (50 Hz Test Supply detected)
8.6 Hz flicker (60 Hz Test Supply detected)
1 Hz
1 Hz flicker
Table 3: Typical Pst results measured to EN/IEC 61000-3-3
6.2 Harmonics Load Operation
The typical current harmonics disturbance generated by the HFG02 in each of the
harmonics modes when tested according to EN/IEC 61000-3-2 is shown below:
Figure 7: Disturbances generated in Fixed Harmonic mode
York EMC Services
HFG02 Operation Manual
(50 Hz or 60 Hz Test Supply detected)
Page 17 of 25
Doc. No. Y0321/DOC/024 Rev. 3
Pst
Plt
1.10
1.10
1.06
1.06
0.45
0.45