Mira Sport Installation, Operation, Maintenance Manual page 24

10.8 kw electric showers
Hide thumbs Also See for Sport:
Table of Contents

Advertisement

3.8. Remove the outlet connector from the heater tank.
3.9. Remove the flow valve from the PCB assembly, inlet connector assembly and the
heater tank.
3.10. Make a note of the positions of the solenoid wires. Remove the solenoid wires
from the solenoid.
3.11. Remove the flow valve.
3.12. Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions.
Terminal Block
24
Inlet Connector
Assembly
Clamp Bracket
Flow Valve Assembly - Removal and Installation
Cover Retaining
Screw
PCB
Assembly
Clamp Bracket
Retaining Screws
Flow Valve
Assembly
Retaining Screw
Heater Tank
Outlet
Connector
Heater Tank
Retaining Screws

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents