Processing Unit; Cable; Processing Unit To Sensor Unit Cable; Interface - Simrad HS52 Instruction Manual

Gps compass and dgps navigator
Table of Contents

Advertisement

2.8

Cable

2.9

Interface

20222360 / E

Processing Unit

IEC 60945 Category: ..................................................... Protected
Enclosure material: ........................... Plastic/Anodized aluminum
Enclosure protection: ............................................................IP-44
Operating temperature range: ........... -25 to +55ºC (-13 to 131°F)
Storage temperature range: ............... -25 to +60ºC (-13 to 140°F)
Safe distance to standard compass:.......................... 0.3 m (1.0 ft)

Processing Unit to Sensor Unit Cable

Type: ......................................................2x2x0.5 mm
Maximum length:................................................... 100 m (328 ft)
Diameter: ..............................................................10 mm (0.4 in.)
Flame retardation:.....................................................IEC 332-3/A
Configuration:....... Display unit connected to the Processing unit
Data outputs:........................................Three RS-232 serial lines,
Data inputs:.................... One RS-232 and one RS-422 serial line
DGPS corrections: ..... RTCM 104 version 2.2 and SAPOS
Baud rate:...........................................................Max. 38.4 kBaud
HDT, ROT, GGA and GLL data update rates: .......... Up to 20 Hz
HDT, ROT, GGA and GLL data delay:...............Less than 50 ms
ZDA and VTG data update rate:....................................Max 2 Hz
VTG data delay:............................................................ Max 1 sec
ZDA data delay:..................................................................... 1 ms
1PPS signal accuracy:......................................................... 0.5 ms
MTBF: ..............................................................................35000 h
MTTR: ......................................................................................1 h
Data output formats:
• NMEA 0183 DTM, GBS, GGA, GLL, GNS, GRS, GSA,
GST, HDT, RMC, ROT, VTG and ZDA. These messages
are according to IEC 61162-1 and follow the standard
regarding unused fields on talker.
TECHNICAL SPECIFICATIONS
Three RS-422 serial lines,
Ethernet UDP/IP
2
with shield
®
EPS
9