Download Print this page

Safety Warnings Summary; Nebs Compliance Statements - Juniper TCX1000-2D8CMD Quick Start Manual

Tcx1000 series. 2-degree 8-channel multiplexer

Advertisement

CAUTION:
Do not bend fiber-optic cables beyond their minimum bend radius. Bending the cables beyond their
minimum bend radius can damage the cables and cause problems that are difficult to diagnose.
CAUTION:
Do not let fiber-optic cables hang free from the connector. Do not allow fastened loops of cables to
dangle, which stresses the cables at the fastening point.
NOTE:
For instructions about connecting the TCX1000-2D8CMD to other devices, see the TCX1000 Programmable
ROADM Hardware Guide.

Safety Warnings Summary

CAUTION:
Before removing or installing the TCX1000-2D8CMD, attach an ESD strap to an ESD point, and place the
other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the equipment.
Permit only trained and qualified personnel to install or replace TCX1000-2D8CMD components.
Perform only the procedures described in this Quick Start Guide and the TCX1000 documentation. Other services must be
performed only by authorized service personnel.
Before installing the device, read the planning instructions in the TCX1000 Programmable ROADM Hardware Guide to make
sure that the site meets environmental requirements for the TCX1000-2D8CMD.
If the rack or cabinet has stabilizing devices, install them in the rack before mounting or servicing the TCX1000-2D8CMD in the
rack or cabinet.
Before installing or after removing an electrical component, always place it component-side up on a flat antistatic mat or in
an electrostatic bag.
Do not work on the TCX1000-2D8CMD or connect or disconnect cables during electrical storms.
Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal
objects heat up when connected to power and ground and can cause serious burns or become welded to the terminals.

NEBS Compliance Statements

The equipment is suitable for installation as part of the Common Bonding Network (CBN).
The equipment is suitable for installations in Network Telecommunication Facilities.
Copyright © 2018, Juniper Networks, Inc.
TCX1000 2-Degree 8-Channel Multiplexer Quick Start Guide
5

Advertisement

loading