MANAGEMENT OF THE TOUCH CONTROLLER UTILITIES
MANAGEMENT OF UTILITIES
Preliminary descriptions
This topic illustrates the activity of the independent utilities that the Combi oven has.

Temperature regulation

The output is activated when room temperature reaches the operating set point and is reactivated
when the temperature drops below the set temperature.
To set the operating set point, refer to "Setting the cooking cycle"; to set the configuration parameters
"Setting"

Room light;

The room light is switched on/off by touching the reference area:
Control panel fan;
The technical compartment fan is switched on until the operating temperature of the control module
reaches the set temperature with parameter F6 and is switched on again when the temperature rises
beyond that set with parameter F7 (i.e. "F6 + F7").
To set the configuration parameters, see "Setting the configuration parameters".
Turbine;
The type of ventilation management used is managed in "on/off" mode, double speed and with
reverse direction of the fan controlled by a frequency inverter programmed to 540 seconds to turn
right and left.
Steam Reduction;
Steam reduction is activated until the temperature reached by the steam reduction probe reaches
the set temperature of 90 °C.