Logs/Grate and Valve Assembly Removal
It may become necessary to remove the logs/grate and
valve assembly. This task should be performed by a quali-
fied service technician. The base pan does not need to
be removed to service the burner assembly.
1. Remove the two top logs from the log/grate assembly.
These logs are not secured to the assembly with screws.
See Figure 4.3.
Figure 4.3 Remove Top Two Logs
2. Remove screw from each tab at the front of the log/
grate assembly that secures the assembly to the base
pan. See Figure 4.4.
Figure 4.4 Remove Screws from Front Tab
3. Remove screws from log tabs on both ends of the rear
log and remove the log. See Figure 4.5.
Figure 4.5 Remove Screws from Log Tabs
20
Heatilator • CD4236IFTR, CD4236IFTLR, CD4842IFTR, CD4842IFTLR Owner's Manual • 2511-981 Rev. D • 6/18
4. The standard metal refractory will have to be removed
in order to access the valve assembly. This is done
by removing 8 screws (10 screws for CD4842IFTR/
CD4842IFTLR models). There are 4 screws per side
panel, Figure 4.6 shows the 2 screws on the bottom of
panels and Figure 4.7 shows the 2 screws on the top
of the panels. The 2 other screws for CD4842IFTR/
CD4842IFTLR models are located in back wall of firebox
as shown in Figure 4.8. One is up by exhaust baffle
and the other is behind logs and near fireplace bottom.
Figure 4.6 Bottom Screws For Metal Refractory
Figure 4.7 Top Screws For Metal Refractory
Figure 4.8 CD4842IFTR/CD4842IFTLR Extra Metal Refractory Screws
2 EXTRA
SCREWS TO BE
REMOVED FOR
CD4842IFTR
CD4842IFTLR

Advertisement