Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
Wrap the refrigerant pipes and the drain
hose up in the absorbent pad and the
vinyl tape; refer to page 43.
100mm
(4inch)
minimum
600mm
(24inch)
minimum
The designs of the unit and the connection valve are subject to change according to the model.
125mm
(5inch)
or more
600mm
"L" m/ft.
(24inch)
maximum
minimum
100mm(4inch)
minimum
350mm(14inch)
minimum
P
REPARING THE
30mm(1inch) or more
125mm(5inch)
or more
"H" m/ft. maximum
Unit : m(ft.)
Model
07/09
15(49ft 3in)
12
15(49ft 3in)
18
15(49ft 3in)
24
20(65ft 7in)
I
NSTALLATION
L
H
7(23ft)
7(23ft)
7(23ft)
8(26ft 3in)
29
E-