Specifications; Installation Requirements - Mira Sprint 7.5 Installation, Operation, Maintenance Manual

Electric showers
Table of Contents

Advertisement

Section
6
1. Plumbing
1.1. Minimum maintained inlet pressure 0.7 bar for satisfactory operation.
1.2. Maximum static inlet pressure 10 bar.
1.3. Minimum static pressure 0.2 bar to keep the flow valve closed.
2. Electrical
2.1. The Mira Sprint requires a 40 Amp fuse.
2.2. The terminal block will not accept cable larger than 10 mm
3. Standards and Approvals
3.1. This Mira Sprint complies with all relevant directives for EC marking.
Section
7
1. Plumbing
1.1. The Mira Sprint is designed to operate with a minimum maintained inlet pressure
of 0.7 bar up to a maximum static inlet pressure of 10 bar.
1.2. The Mira Sprint is normally connected to the cold water mains-fed supply.
However, the water supply can be taken from a cold water storage cistern, provided
there is a minimum maintained inlet head of water of 7 metres (the vertical distance
from the base of the cold water storage cistern to the shower fitting handset). To
reduce pressure losses and fluctuations, the cistern-fed water supply must be
independent from other supply draw-offs, and should avoid long horizontal pipe
runs and use swept bends rather than 90 ° elbows.
1.3. The Mira Sprint is suitable for installation within the shower area. It is fitted with
a pressure relief device and must be positioned over a water catchment area with
the controls at a convenient height for the user.
10

Specifications

Installation Requirements