2 OPTIONAL PARTS, ACCESORIES AND TOOLS

Optional Installation Parts
Part name
*1
Refrigerant piping
Putty, PVC tapes
*1 Refrigerant piping covered with insulating material (polyethylene form, 6 mm thick).
*
In case the piping is installed above the ceiling, it shall be covered with thicker insulating material (polyethylene form, 10 mm
thick).
Attachment bolt arrangement of outdoor unit
• Secure the outdoor unit with the attachment bolts and nuts if the unit
is likely to be exposed to a strong wind.
• Use 8 mm or 10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple to the
base plate of the outdoor unit before installing it.
Accessory and Installation Parts
Part No.
a
b
c
Others
Important information and warning
B/W strips (Energy efficiency labels)
EN
Indoor unit name
(Abbreviation)
07, 10, 13
16, 18
Part name (Q'ty)
Outdoor unit installation manual x 1
Specifications x 1
CD-ROM x 1
(
Outdoor unit installation manual
Specifications
Name
Specifications
Liquid side
(Outer diameter)
6.35 mm
6.35 mm
Elongated drain
hole
(e)
Part No.
d
e
)
4
Gas side
(Outer diameter)
9.52 mm
12.7 mm
259
Suction side
50
50
280
Diffuser
600
Part name (Q'ty)
Drain nipple x 1
(Heat pump models only)
Water-proof rubber cap x 1
(Heat pump models only)
Q'ty
1 ea.
1 ea.
Drain hole
(d)

Hide quick links: