Receiving - Baldor MN605 Installation And Operating Manual

Integral horsepower
Table of Contents

Advertisement

Safety Notice Continued
WARNING:
UL Listed motors must only be serviced by UL Approved Authorized Baldor Service Centers if these
motors are to be returned to a hazardous and/or explosive atmosphere.
WARNING:
This equipment is at line voltage when AC power is connected. Disconnect and lockout all ungrounded
conductors of the ac power line before proceeding. Failure to observe these precautions could result in
severe bodily injury or loss of life.
WARNING:
Rotating parts can cause serious or fatal injury. If relubrication is performed with the motor running, to
avoid injury do not contact any rotating parts.
WARNING:
Solvents can be toxic and/or flammable. Follow manufacturer's safety procedures and directions.
WARNING:
Space Heaters operate at line voltage. Disconnect power to space heaters before performing
maintenance work on motor. Failure to observe this precaution could result in severe bodily injury or
loss of life.
WARNING:
Thermostat contacts automatically reset when the motor has slightly cooled down. To prevent injury or
damage, the control circuit should be designed so that automatic starting of the motor is not possible
when the thermostat resets.
Caution:
To prevent premature equipment failure or damage, only qualified maintenance personnel should
perform maintenance.
Caution:
Do not over−lubricate motor as this may cause premature bearing failure.
Caution:
Do not lift the motor and its driven load by the motor lifting hardware. The motor lifting hardware is
adequate for lifting only the motor. Disconnect the load (gears, pumps, compressors, or other driven
equipment) from the motor shaft before lifting the motor.
Caution:
If eye bolts are used for lifting a motor, be sure they are securely tightened. The lifting direction should not
exceed a 20 ° angle from the shank of the eye bolt or lifting lug. Excessive lifting angles can cause damage.
Caution:
Do not use the coupling to compensate for poor alignment. This can result in vibration, noise, coupling
wear, overloaded bearings and early failure.
Caution:
To prevent equipment damage, be sure that the electrical service is not capable of delivering more than
the maximum motor rated amps listed on the rating plate.
Caution:
If a Motor Insulation test (High Potential Insulation test) must be performed, disconnect the motor from
any Speed Control or drive to avoid damage to connected equipment.
Caution:
Do not use Silicone grease or Sealing Compounds (RTV) on or in the vicinity of the motor or its air
supply. Silicone vapor inside the motor will result in extremely rapid brush wear.
Caution:
Series wound motors must never be allowed to run with no load (broken belt etc.) An unloaded motor
may reach destructive high speeds.
Caution:
Motors designed for forced ventilation must have cooling air when fields are excited at rated voltage.
Installations having the air supply interrupted when the motor is not operating must have field
disconnected or field voltage reduced to 50% rated by means of field economizing resistor and relay or
motor insulation life will be significantly reduced.
If you have any questions or are uncertain about any statement or procedure, or if you require additional
information please contact your Baldor District Office.

Receiving

Each Baldor Electric Motor is thoroughly tested at the factory and carefully packaged for shipment. When you
receive your motor, there are several things you should do immediately. Do not unpack until ready for use.
1.
Observe the condition of the shipping container and report any damage immediately to the commercial
carrier that delivered your motor.
2.
Verify that the part number of the motor you received is the same as the part number listed on your purchase order.
Lifting Magnet Generators
Treat Baldor lifting magnet generators like motors during installation or maintenance.
Generally, they have standard compound self-excited fields. Standard magnetism is for counter-clockwise
rotation (facing the drive end of the motor). To reverse (operate clockwise), refer to the connection diagrams in
Section 4 of this manual.
Caution:
Do not lift the motor and its driven load by the motor lifting hardware. The motor lifting hardware is
adequate for lifting only the motor. Disconnect the load (gears, pumps, compressors, or other driven
equipment) from the motor shaft before lifting the motor.
Handling
The motor should be lifted using the lifting lugs or eye bolts provided.
1.
Use the lugs or eye bolts provided to lift the motor. Never attempt to lift the motor and additional
equipment connected to the motor by this method. The lugs or eye bolts provided are designed to lift only
the motor. Never lift the motor by the motor shaft or the hood of a WPII motor. If eye bolts are used for
lifting a motor, be sure they are securely tightened. The lifting direction should not exceed a 20° angle from
the shank of the eye bolt. Excessive lifting angles can cause motor damage.
2.
To avoid condensation inside the motor, do not unpack until the motor has reached room temperature.
(Room temperature is the temperature of the room in which it will be installed). The packing provides
insulation from temperature changes during transportation.
3.
When lifting a WPII (Weather Proof Type 2) motor, do not lift the motor by inserting lifting lugs into holes on
top of the cooling hood. These lugs are to be used for hood removal only. A spreader bar should be used
to lift the motor by the cast lifting lugs located on the motor frame.
1-2
MN605

Advertisement

Table of Contents
loading

Table of Contents