INSTALLATION AND CONFIGURATION
The following shows the DHCP Client screen.

2.6.17 WAG Circuit ID

Every WAG that is operating as a gateway to the office must have a unique Circuit ID. The Circuit
ID is used by the office to know which WAG on the Ethernet LAN ATCS messages should be
routed to in order to reach type 7 devices that the WAG is connected to.
The WAG Circuit ID consists of three data fields and defaults to 000.0.00 (Disabled).
To Change the WAG Circuit ID:
1.
On the Second Configuration Menu, select "WAG Circuit ID" to be changed. The Change WAG
Routing Region screen appears.
Figure 2-42. Change WAG Routing Region Screen – Initial Screen
2.
From this initial screen (Figure 2-42), do one of the following:
a. To leave the three digits of the first field of a currently assigned WAG Circuit ID
unchanged, press ENTER. Go to step 3.
b. To change the three digits of the first field of the WAG Circuit ID, type the digits and then
press ENTER. Entry can be any value from 1 to 999. Go to step 3.
c. To disable the WAG Circuit ID and set it to the default value, enter 0 (zero) and then press
ENTER. The user is returned to the Second Configuration Menu.
3.
From the screen in figure 2-43, do one of the following:
a. To leave the digit of the second field of a currently assigned WAG Circuit ID unchanged,
press ENTER. Go to step 4.
Document No.: COM-00-05-16
Version: C.1

Figure 2-41. DHCP Client

2-32
June 2006, Revised June 2014