Binary Output Operations; Bo Trip/Reset On Battery/Usb; Bo Trip/Reset On Ct Input Or Auxiliary Voltage - Siemens 7SR45 Argus User Manual

Self powered/dual powered non-directional overcurrent and earth fault relay
Hide thumbs Also See for 7SR45 Argus:
Table of Contents

Advertisement

Parameters
50-1
50-2
51-1
50N-1
50N-2
51N-1
50G-1
50G-2
51G-1
50LC
#
Active Grp 1
#
Active Grp 2
General Pickup
Prot'n Healthy
Low Battery
IRF
#
Local mode
#
Remote mode
#
Out of Service mode
BI1 Operated
BI2 Operated
BI3 Operated *
BI4 Operated *
NOTE:
* For all 7SR4501 variants, these parameters are not available.
NOTE:
#
For 7SR4501-xGA10-1AA0 variant, these parameters are not available.
NOTE:
If a binary output is assigned to IRF, do not use the same binary output for any other functions.

3.13 Binary Output Operations

The relay reset can be performed from the Relay Identifier Screen > TEST/RESET► key.
If the fault current persists and if the user presses TEST/RESET► key, the pop-up message appears,
"FAULT PERSISTS".
Based on the availability of power source, the flag can be reset by using any one of the following conditions:
3.13.1

BO Trip/Reset on Battery/USB

In this mode, the relay uses the power from battery/USB to operate/reset the binary output and takes
approximately 4s to perform the action.
If the consecutive commands are provided within 4 seconds, the relay performs delayed operations and displays
a pop-up message appears on the HMI "INSUFFICIENT ENERGY".
3.13.2

BO Trip/Reset on CT Input or Auxiliary Voltage

In this mode, the relay can operate/reset the binary outputs instantaneously.
©2018 Siemens Protection Devices Limited
Table 3-14
Description
50-1 element operate
50-2 element operate
51-1 element operate
50N-1 element operate
50N-2 element operate
51N-1 element operate
50G-1 element operate
50G-2 element operate
51G-1 element operate
50LC/SOTF element operate
Active Group 1
Active Group 2
Pickup detected
Protection Healthy
Battery Volts low indication
Internal Relay Failure
Local mode
Remote mode
Out of Service mode
BI-1 operated
BI-2 operated
BI-3 operated
BI-4 operated
Chapter 1 - 7SR45 Description of Operation
Binary Output
Default Value
Min
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 (BO1), - (Others)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Step
Max
Change
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
1
-
Chapter 1 Page 40 of 48