Abbreviated Names, Generic Names And Terms - Mitsubishi Electric AJ65BT-RPI-10A User Manual

Cc-link system space optical repeater module
Table of Contents

Advertisement

1.3 Abbreviated names, generic names and terms

Abbreviated names, generic names and terms Description
Abbreviated names,
generic names and terms
AJ65BT-RPI-10A/10B
AJ65SBT-RPT
AJ65SBT-RPS/RPG
AJ65FBTA-RPH
AJ65BTS-RPH
A module
B module
Segment
Master station
Local station
Remote I/O station
Remote device station
Remote station
Intelligent device station
Repeater
Ready master station
Built-in CC-Link function
Master local module
Master module
Local module
Remote module
Intelligent device module Module allowing transient transmission such as AJ65BT-R2.
Abbreviation of AJ65BT-RPI-10A/AJ65BT-RPI-10B type CC-Link
system space optical repeater module
Abbreviation of AJ65SBT-RPT type CC-Link system repeater (T-
junction) module.
Abbreviation of AJ65SBTRPS/AJ65SBT-RPG type CC-Link system
optical repeater module.
Abbreviation of AJ65FBTA-RPH type CC-Link system low profile
waterproof type repeater hub module.
Abbreviation of AJ65BTS-RPH type CC-Link system spring clamp
terminal block type repeater hub module.
Abbreviation of AJ65BT-RPI-10A type CC-Link system space
optical repeater module
Abbreviation of AJ65BT-RPI-10B type CC-Link system space
optical repeater module
System between terminating resistances connected to each other
through cross-over cables.The conventional CC-Link system can
be said to be configured with one segment (Refer to Section 2.1.).
Station to control the data link system. One station is required for
each system.
Station which has a sequencer CPU and can communicate with the
master station and the other local stations.
Remote station processing only information in unit of bit.
(AJ65BTB1-16D, AJ65SBTB1-16D, AJ65SBTB1-8, etc.)
Remote station processing only information in unit of bit and in unit
of word.(AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI, etc.)
Generic name of remote I/O station and remote device station.
Controlled by the master station.
Station allowing transient transmission such as AJ65BT-R2.
(Including local stations)
Module for expanding the CC-Link system by connecting the
segments to each other.
Backup station which inherits data link control when the master
station comes off parallel due to error.
Abbreviation of built-in CC-Link system master/local functions of the
L26CPU-BT and L26CPU-PBT
Generic name of RJ61BT11, QJ61BT11N, QJ61BT11, built-in CC-
Link function, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11
Generic name of the master local module that is used as a master
station
Generic name of the master local module that is used as a local
station
Generic name of AJ65BTB1-16D, AJ65SBTB1-16D,
AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI and A852GOT.
4
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj65bt-rpi-10b

Table of Contents