Robertshaw 200-403 Installation Instructions
Robertshaw 200-403 Installation Instructions

Robertshaw 200-403 Installation Instructions

Heating or cooling thermostats 200 series

Advertisement

Quick Links

CONTROLS COMPANY
The Energy Control Company
The 200 Series Thermostats are decorator designed and engineered
for outstanding performance. All models feature Uni-Line's famous
sealed-in-glass switch which requires NO LEVELING AND OPTI-
MUM PROTECTION FROM SWITCH CONTAMINATION.
Models are available for 24 volt heating or cooling, millivolt heating,
2- or 3-wire zone, and with energy saving heating or cooling ranges.
A decorating wall plate is included with all models to cover old ther-
mostat mounting marks. (See photo at right.)
THIS DEVICE SHOULD BE INSTALLED BY A QUALIFIED SERVICE
TECHNICIAN WITH DUE REGARD FOR SAFETY, AS IMPROPER
INSTALLATION COULD RESULT IN A HAZARDOUS CONDITION.

SPECIFICATIONS

Heat anticipation range
24 volt heating. . . . . . . . . . . . . . . . . . . . . . . . . .18 to 1.0 Amps
Millivolt and 2-wire zone . . . . . . . . . . . . . . . . . . . . . . . . . . none
Cooling and 3-wire zone. . . . . . . . . . . . . . . . . . . . 4700Ω, fixed
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48°-65°F
except
200-403 and 503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39°-77°F
200-405 and 505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48°-65°F
200-406 and 506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39°-65°F
200-605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78°-86°F
Dimensions. . . . . . . . . . . . . . . . . . . . . . . 2-13/16" rounded square
INSTALLATION INSTRUCTIONS
Shut off power equipment before servicing
LOCATING THERMOSTAT
Your thermostat is a sensitive instrument. For accurate temperature
control and comfort, correct location is very important.
On new installations, the guidelines listed below should be followed as
closely as possible. When replacing an old thermostat, install the new
one in the same location unless these guidelines suggest otherwise.
1. Locate the thermostat on an inside wall about five feet off the
floor where it is easy to install, service, and adjust. It should be
in a room that is used often, such as a living room or family room.
LITHO IN U.S.A. 11/00
®
CAUTION
1-5/16" deep
FIGURE 1
COVER
FIGURE 2
SUBBASE
©2000 Robertshaw Control Company
I I N N S S T T A A L L L L A A T T I I O O N N D D A A T T A A

HEATING OR COOLING

Electrical rating
24 volt models . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 VAC max.
Millivolt models . . . . . . . . . . . . . . . . . . . . . 250 to 750 millivolts
Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2°F (nominal)
Switch action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPST
FIGURE 3 - BODY
2. Do not install it where there are unusual heating conditions, such
as in direct sunlight, or near a lamp, radio, television, radiator,
register, fireplace, or other heat producing appliance. Also,
check for hot water pipes within the wall, or a stove on other side
of wall.
3. Do not locate in unusual cooling conditions, such as on an out-
side wall, on a wall separating an unheated room, or in drafts
from stairwells, doors, or windows.
200 SERIES
THERMOSTATS
1.0 Amp max.
except SPDT 200-901
1-190D
30965E

Advertisement

loading

Summary of Contents for Robertshaw 200-403

  • Page 1: Heating Or Cooling

    Switch action ........SPST 200-403 and 503 ......39°-77°F except SPDT 200-901 200-405 and 505 .
  • Page 2 5. Keeping hands and breath away from bimetal temperature sens- ing element (Figure 3), turn calibration shaft in center of bimetal ROBERTSHAW CONTROLS COMPANY • UNI-LINE NORTH AMERICA • P.O. BOX 2000 • CORONA, CA 92879-1736...

This manual is also suitable for:

200-405200-406200-605200-503200-505200-506 ... Show all