Omron HEM-7200 Instruction Manual

Omron HEM-7200 Instruction Manual

Automatic blood pressure monitor

Advertisement

Quick Links

1. Overview
Main unit:
A
B
Automatic Blood
F
C
Pressure Monitor
E
D
Model HEM-7200
A. Display
Instruction Manual
B. START/STOP button
C. Memory button
5325397-5B
D. Up/Down (
) buttons
E. Date/Time setting (
) button
Introduction
Thank you for purchasing the OMRON HEM-7200 Automatic Blood Pressure
Monitor.
Arm cuff:
The OMRON HEM-7200 is a compact, fully automatic blood pressure monitor,
I
J
K
operating on the oscillometric principle. It measures your blood pressure and
pulse rate simply and quickly. For comfortable controlled inflation without the
need of pressure pre-setting or re-inflation the devices uses its advanced
"IntelliSense" technology.
Please read this instruction manual thoroughly before using the unit.
Please keep for future reference.
L
For specific information about your own blood pressure, CONSULT YOUR
DOCTOR.
Storage case:
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia
or arteriosclerosis.
Please read this section carefully before using the unit.
Warning:
• Indicates a potentially hazardous situation which, if not avoided, could result
Display:
M
in death or serious injury.
(General Usage)
N
• Always consult your doctor. Self-diagnosis of measurement results and
self-treatment are dangerous.
O
• People with severe blood flow problems, or blood disorders, should consult a
P
doctor before using the unit, as cuff inflation can cause internal bleeding.
Q
(AC Adapter Usage)
• Never plug in or unplug the power cord from the electric outlet with wet
R
hands.
S
(Battery Usage)
T
• If battery fluid should get in your eyes, immediately rinse with plenty of clean
water. Consult a doctor immediately.
M. Systolic blood pressure
Caution:
N. Diastolic blood pressure
• Indicates a potentially hazardous situation which, if not avoided, may result in
O Heartbeat symbol
minor or moderate injury to the user or patient or damage to the equipment or
(Flashes during measurement)
other property.
P. Memory symbol
(General Usage)
Q. Deflation symbol
• Do not leave the unit unattended with infants or persons who cannot express
R. Average value symbol
their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Do not disassemble the unit or arm cuff.
2. Preparation
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result
in incorrect measurement results.
2.1 Installing/Replacing the Batteries
• Make sure that the air tube is not wrapped around other parts of your body
when taking measurements at night. This could result in injury when the air
1.
Remove the battery cover.
pressure in the air tube is increased.
• Do not leave the cuff wrapped on the arm if taking measurements during the
2.
Insert four "AA" batteries
night. This could result in injury.
• Do not inflate the arm cuff over 299 mmHg.
as indicated in the battery
• Do not use a mobile phone or other devices that emit electromagnetic fields,
compartment and then
near the unit. This may result in incorrect operation of the unit.
replace the battery cover.
• Do not operate the unit in a moving vehicle (car, airplane).
• To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it
Notes:
can cause internal bleeding.
• If the battery low symbol (
(AC Adapter Usage)
then replace all batteries at the same time.
• Use only the original AC adapter (optional) designed for this unit. Use of
• The measurement values continue to be stored in memory even after
unsupported adapters may damage and/or may be hazardous to the unit.
the batteries are replaced.
• Plug the AC adapter into the appropriate voltage outlet. Do not use a
Disposal of used batteries should be carried out in accordance with the
multiple-tap.
• Do not use the AC adapter if the unit or the power cord is damaged. Turn off
national regulations for the disposal of batteries.
the power and unplug the power cord immediately.
(Battery Usage)
2.2 Setting the Date and Time
• If battery fluid should get on your skin or clothing, immediately rinse with
plenty of clean water.
1.
Press the
button.
• Use only four "AA" alkaline or manganese batteries with this unit. Do not use
other types of batteries.
2.
Set the monitor to the correct date and time before
• Do not insert the batteries with their polarities incorrectly aligned.
taking a measurement for the first time.
• Replace old batteries with new ones immediately. Replace all four batteries at
the same time.
• Remove the batteries if the unit will not be used for three months or more.
1)
• Do not use new and used batteries together.
General Precautions
• Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
2)
• Do not take measurements after bathing, drinking alcohol, smoking,
exercising or eating.
• Do not forcibly bend the arm cuff or bend the air tube excessively.
• When removing the air tube, pull on the air plug at the connection with the
main unit not the tube itself.
Year
• Do not inflate the arm cuff when it is not wrapped around your arm.
Month Day
• Do not wash the arm cuff or immerse it in water.
• Read and follow the "Important information regarding Electro Magnetic
Compatibility (EMC)" in the Technical Data Section.
3.
Press the START/STOP button to store the setting.
• Read and follow the "Correct Disposal of This Product" in the Technical Data
Notes:
Section when disposing of the device and any used accessories or optional
• If the batteries have been removed for 30 seconds or more, the date
parts.
and time setting will need to be reset.
• If the date and time are not set, "-:--" appears during or after
measurement.
3. Using the Unit
G
3.1 Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your
upper arm.
Do not place the cuff over thick clothes.
H
1.
Insert the air plug into the air jack.
F. Air Jack
G. Battery compartment
H. AC adapter jack (for optional AC
adapter)
2.
Put your arm through the cuff loop.
I. Arm cuff (Medium cuff: arm
circumference 22-32cm)
J. Coloured Marker
K. Air tube
L. Air plug
3.
Position the arm correctly.
U
The bottom edge of the cuff should be 1 to 2 cm above the elbow.
Marker (arrow under tube) is centred on the middle of your inner arm.
V
Close the fabric fastener FIRMLY.
1 to 2 cm
W
X
S. Movement error symbol
Notes:
T. Date/Time display
• When you take a measurement on the right
U. Blood pressure level indicator
arm, air tube will be at the side of your
elbow. Be careful not to rest your arm on
V. Pulse display
W. Battery low symbol
the air tube.
X. Irregular heartbeat symbol
• The blood pressure can differ between the right arm and the left arm,
and therefore also the measured blood pressure values can be
different. Omron recommends to always use the same arm for
measurement. If the values between the two arms differ substantially,
please check with your doctor which arm to use for your
measurement.
3.2 How to Sit Correctly
To take a measurement, you need to be
relaxed and comfortably seated, under
comfortable room temperature. No eating,
smoking or exercising 30 minutes before
taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
) appears on the display, turn the unit off
• The cuff should be at the same level as your
heart.
3.3 Taking a Reading
Notes:
• To cancel a measurement, press the START/STOP button to turn off
the unit and to release the air in the arm cuff.
• Remain still while taking a measurement.
1.
Press the START/STOP button.
The cuff will start to inflate automatically.
Push
or
buttons to
START
INFLATE
DEFLATE
END
COMPLETE
change.
Push the
button to confirm.
Next setting appears.
Hour Minute
If your systolic pressure is more than
220 mmHg
After the cuff starts to inflate, press and hold the
START/STOP button until the monitor inflates 30 to 40 mmHg
higher than your expected systolic pressure.
Notes:
• The monitor will not inflate above 300 mmHg.
• Do not apply more pressure than necessary.
Note: Wait 2-3 minutes before taking another blood pressure
4. Troubleshooting and Maintenance
measurement. Waiting between readings allows the arteries to
4.1 The Icons and Error Messages
return to the condition prior to taking the blood pressure
measurement.
Error Display
C
a
u
s
e
Warning:
Self-diagnosis of measured results and treatment are dangerous.
Irregular or weak pulses are
Please follow the instructions of your doctor.
detected.
2.
Remove the arm cuff.
Movement during
measurement.
3.
Press the START/STOP button to turn off the monitor.
The monitor automatically stores the measurement in its
memory.
Blink
The batteries are low.
It will automatically turn off after five minutes.
Important:
The batteries are
Lit
exhausted.
• Recent research suggests that the following
values can be used as a guide to high blood
pressure for measurements taken at home.
Cuff is under inflated.
Movement during
Systolic Blood Pressure
Above 135 mmHg
measurement.
Diastolic Blood Pressure
Above 85 mmHg
This criteria is for home blood pressure measurement.
Air plug disconnected.
• Your blood pressure monitor includes an irregular
heartbeat feature. Irregular heartbeats can influence
Arm cuff not applied
the results of the measurement. The irregular
correctly.
heartbeat algorithm automatically determines if the
measurement is usable or needs to be repeated. If the
Clothing is interfering with
measurement results are affected by irregular
the arm cuff.
heartbeats but the result is valid, the result is shown
together with the irregular heartbeat symbol (
). If the
irregular heartbeats cause the measurement to be
Air is leaking from the arm
invalid, no result is shown. If the irregular heartbeat
cuff.
symbol (
) is shown after you have taken a measurement, repeat
the measurement. If the irregular heartbeat symbol (
) is shown
The arm cuff was inflated
frequently, please make your doctor aware of it.
above 299 mmHg when
inflating the cuff manually.
3.4 Using the Memory Function
The monitor automatically stores the result up to 60 sets. It can also
Device error.
calculate an average reading based on the measurements from the last
three readings taken within 10 minutes. If there are only two readings in
memory for that period, the average will be based on two readings. If
there is one reading in memory for that period, the average will be
based on one reading.
Notes:
• If the memory is full, the monitor will delete the oldest readings.
4.2 Troubleshooting
• When viewing the reading taken without setting the date and time,
"-:--" is displayed instead of the date and time.
Problem
Cause
Average Value
Previous Reading
Arm cuff not applied
Alternating
correctly.
date/time display
The reading is
Movement or talking
extremely low (or
during measurement.
high).
Old
Recent
Clothing is interfering
View the Average
View the Previous
View the Readings
with the arm cuff.
Value
Reading
Stored in Memory
• If the previous
• The Memory number
reading was taken
appears for a second
The air tube is not
without setting the
before the pulse rate
securely connected
date and time, the
is displayed. The
into the main unit.
Arm cuff pressure
average value is not
newest set is
does not rise.
calculated.
numbered "1".
Air is leaking from the
arm cuff.
To delete all the values stored in memory
When the memory symbol (
) appears, first press the Memory
Arm cuff deflates too
The arm cuff is loose.
soon.
button. Then while holding it down, press the START/STOP button
simultaneously for about 2-3 seconds.
Cannot measure or
The arm cuff has not
readings are too low
been inflated
or too high.
sufficiently.
The batteries are
empty.
Nothing happens
Note: You cannot partially delete the stored readings.
when you press the
The batteries have
buttons.
been inserted
incorrectly.
• Press the START/STOP button and repeat
measurement.
• If the problem continues, try replacing the
Other problems.
batteries with new ones.
If this still does not solve the problem, contact
your OMRON retail outlet or distributor.
4.3 Maintenance
To protect your unit from damage, please observe the following:
• Do not subject the main unit and the cuff to extreme
R
e
m
e
d
y
temperatures, humidity, moisture or direct sunlight.
• Do not fold the cuff or tubing tightly.
Remove the arm cuff. Wait
2-3 minutes and then take
• Do not inflate the arm cuff over 299 mmHg.
another measurement.
• Do not disassemble the unit.
Repeat the steps in section
• Do not subject the unit to strong shocks or vibrations
3.3. If this error continues to
(for example, dropping the unit on the floor).
appear, contact your doctor.
• Do not use volatile liquids to clean the main unit. The
Carefully read and repeat
unit should be cleaned with a soft, dry cloth.
the steps in section 3.3.
• Use a soft, moistened cloth and soap to clean the arm
You should replace them
cuff.
with new ones ahead of
• Do not wash the arm cuff or immerse it in water.
time.
• Do not use petrol, thinners or similar solvents to clean
Refer to section 2.1.
the arm cuff.
You should replace them
with new ones at once.
Refer to section 2.1.
Carefully read and repeat
the steps listed under
section 3.3.
Repeat measurement.
Remain still and do not talk
during measurement.
Refer to section 3.3.
Insert the air plug securely.
Refer to section 3.1.
Apply the arm cuff correctly.
Refer to section 3.1.
• Do not carry out repairs of any kind yourself. If a defect
Remove any clothing
occurs, consult your local authorised OMRON
interfering with the arm cuff.
distributor or dealer.
Refer to section 3.1.
Calibration and Service
Replace cuff with new one.
• The accuracy of this blood pressure monitor has been
Refer to Chapter 5.
carefully tested and is designed for a long service life.
• It is generally recommended to have the unit inspected
Do not inflate the arm cuff
above 299 mmHg.
every two years to ensure correct functioning and
Refer to section 3.3.
accuracy. Please consult your local authorised
OMRON distributor or dealer.
Contact your OMRON retail
4.4 Storage
outlet or distributor.
Keep the unit in its storage case when not in use.
1.
Unplug the air tube from the air connector.
2.
Gently fold the air tube into the arm cuff.
Note:
Remedy
Do not bend the air tube excessively.
Apply the arm cuff
correctly.
Refer to section 3.1.
Remain still and do not
3.
Place the arm cuff and main unit in the
talk during
storage case.
measurement.
Refer to section 3.3.
Remove any clothing
Do not store the unit in the following situations:
interfering with the arm
• If the unit is wet.
cuff.
• Locations exposed to extreme temperatures,
Refer to section 3.2.
humidity, direct sunlight, dust or corrosive
Make sure that the air
vapours.
tube is connected
• Locations exposed to vibrations, shocks or where it will be at an
angle.
securely.
Refer to section 3.1.
Replace the arm cuff
with a new one.
Refer to Chapter 5.
5. Optional Parts
Apply the cuff correctly
Medium Arm Cuff
Large Arm Cuff
AC Adapter "R"
so that it is firmly
Arm circumference
Arm circumference
wrapped around the arm.
22 - 32 cm
32 - 42 cm
Refer to section 3.1.
Inflate the cuff so that it
is 30 to 40 mmHg above
your previous
measurement result.
Refer to section 3.3.
Using the Optional AC Adapter
Replace the batteries
with new ones.
1.
Insert the AC adapter plug
Refer to section 2.1.
into the AC adapter jack on
Insert the batteries with
the rear side of the main
the correct (+/-) polarity.
unit.
Refer to section 2.1.
2.
Plug the AC adapter into an
electrical outlet.
To disconnect the AC adapter, unplug the AC adapter from the
electrical outlet first and then remove the AC adapter plug from the
main unit.
HEM-7200-C1_B_M02_100309.pdf
6. Technical Data
Product Description
Automatic Blood Pressure Monitor
Model
HEM-7200
Display
LCD Digital Display
Measurement Method
Oscillometric method
Measurement Range
Pressure: 0 mmHg to 299 mmHg
Pulse: 40 to 180/min.
Accuracy
Pressure: ±3 mmHg
Pulse: ±5% of display reading
Inflation
Fuzzy-logic controlled by electric pump
Deflation
Automatic pressure release valve
Pressure Detection
Capacitive pressure sensor
Memory
60 Measurements with date and time
Rating
DC6V
4W
Power Source
4 "AA" batteries 1.5V or AC adapter
(optional)
Battery Life
Capacity of new alkaline batteries is approx.
1500 measurements
Applied Part
= Type B
Protection Against
Internally powered ME equipment
Electric Shock
(When using only the batteries)
= Class II ME equipment
(Optional AC adapter)
Operating
+10°C to +40°C / Maximum: 30 to 90% RH
temperature/ Humidity
Storage temperature/
-20°C to +60°C / Maximum: 10 to 95% RH
Humidity/ Air pressure
/ 700-1060 hPa
Console Weight
Approximately 340g without batteries
Cuff Weight
Approximately 120g
Outer Dimensions
Approximately 123 (w) mm × 85 (h) mm × 141(l) mm
Cuff Dimensions
Approximately 146 mm × 446 mm (Medium cuff: arm
circumference 22 to 32 cm)
Cuff Material
Nylon and polyester
Package Content
Main unit, cuff, instruction manual, storage case,
battery set
Notes:
• Subject to technical modification without prior notice.
• Disposal of this product and used batteries should be carried out in
accordance with the national regulations for the disposal of electronic
products.
Please read this instruction manual carefully before using the device.
• This device fulfils the provisions of EC directive 93/42/EEC (Medical Device
Directive).
• This blood pressure monitor is designed according to the European Standard
EN1060, Noninvasive sphygmomanometers Part 1: General Requirements
and Part 3: Supplementary requirements for electromechanical blood
pressure measuring systems.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC's and mobile
(cellular) telephones, medical devices in use may be susceptible to
electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of the medical
device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility)
with the aim to prevent unsafe product situations, the EN60601-1-2:2007
standard has been implemented. This standard defines the levels of immunity to
electromagnetic interferences as well as maximum levels of electromagnetic
emissions for medical devices.
This medical device manufactured by OMRON HEALTHCARE conforms to this
EN60601-1-2:2007 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate
strong electrical or electromagnetic fields, near the medical device. This may
result in incorrect operation of the unit and create a potentially unsafe situation.
Recommendation is to keep a minimum distance of 7 m. Verify correct
operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON
HEALTHCARE EUROPE at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it
should not be disposed of, with other household wastes at the end
of its working life. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate
this from other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can
take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions
of the purchase contract. This product should not be mixed with other commercial
wastes for disposal.
This product does not contain any hazardous substances.
OMRON HEALTHCARE Co., Ltd.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto
615-0084 JAPAN
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp THE NETHERLANDS
OMRON HEALTHCARE SINGAPORE PTE LTD.
Asia Pacific HQ
438A Alexandra Road, #05-05/08, Alexandra Technopark,
Singapore 119967

Advertisement

loading