System expansions

Installing and removing a power supply module

If the power-on indicator of a power supply module goes off during operation, then
the module is defective and must be replaced. If the server has three power supply
modules, trouble-free replacement can be carried out during operation.
The power supply must be set to the local line voltage (115 V for 100 V -
!
125 V and 230 V for 200 V - 240 V). During current operation you must
not remove several power supply modules at the same time.
Turn both quarter-turn fasteners counterclockwise (1) and remove the power
Ê
supply module or the bay cover from the server (2).
Make sure that the new power supply module is set to the correct line
!
voltage (switch at the right of the power supply module).
58
Installing and removing a power supply module
1
2
1