Sample CLI sessions
CLI(config-if-ip)# no ip nat
CLI(config-if-ip)# ip address alternate 192.168.23.56
CLI(config-if-ip)# end
CLI(config)# end
CLI# quit
Example 2
This sample CLI session shows you how to create a static trunk on the E-MSM720 that is
bound to a network profile called static trunk on port 2. The trunk is created on trunk group
1 using a VLAN ID of 900 (tagged).
CLI> enable
CLI# config
CLI(config)# network-profile "static trunk"
CLI(network-profile)# vlan 900
CLI(network-profile)# vlan
CLI(network-profile)# default
CLI(network-profile)# end
CLI(config)# interface 1
CLI(if)# trunk type trunk
CLI(if)# trunk group 1
CLI(if)# end
CLI(config)# interface 2
CLI(if)# trunk group 1
CLI(if)# trunk type trunk
CLI(if)# end
CLI(config)#
Example 3
This sample CLI session shows you how to create a dynamic trunk on the E-MSM720 that is
bound to a network profile called lacp trunk on ports 5 and 6. The trunk is created using a
VLAN ID of 800 (tagged).
CLI> enable
CLI# config
CLI(config)# network-profile "lacp trunk"
CLI(network-profile)# vlan 800
CLI(network-profile)# vlan
CLI(network-profile)# default
CLI(network-profile)# end
CLI(config)# interface 1
CLI(if)# trunk type lacp
CLI(if)# end
CLI(config)# interface 2
CLI(if)# trunk type lacp
CLI(if)# end
1-11