Honeywell VR8215S Installation Instructions Manual page 8

Tradeline direct ignition combination gas controls
Table of Contents

Advertisement

Available languages

Available languages

VR8215S,T TRADELINE DIRECT IGNITION COMBINATION GAS CONTROLS
After servicing, verify proper system operation.
If Main Burner Does Not
Come On With Call For Heat
1. Confirm the gas control switch is in the ON position.
2. Adjust thermostat several degrees above room tem-
perature.
3. Using ac voltmeter, measure across the quick con-
nect terminals at gas control.
4. If voltage is incorrect or not present, check control
circuit for proper operation.
5. If proper voltage is present, replace gas control.
INSTRUCTIONS TO
THE HOMEOWNER
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:
1. Before lighting, smell around the appliance for
gas. Be sure to smell next to the floor because
LP gas is heavier than air. If you smell gas:
a. Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
the gas supply at the gas tank.
b. Do not light any appliances in the house.
c. Do not touch electrical switches or use the
phone.
d. Leave the building and use a neighbor's
phone to call your gas supplier.
e. If you cannot reach your gas supplier, call
the fire department.
2. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
IMPORTANT
Follow the operating instructions provided by the
heating appliance manufacturer. The information
below describes a typical control application, but
the specific controls used and the procedures
outlined in your appliance manufacturer
instructions can differ, requiring special
instructions.
34-00006EF—01
To Turn ON Appliance
STOP! Read the Warnings
Above Before Proceeding.
1. The lighting sequence on this appliance is
automatic; do not attempt to manually light the main
burner.
2. If the furnace does not come on when the
thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.
3. Remove the burner access panel if provided on
your appliance.
4. Push the on-off switch to the OFF
position.
5. Wait five minutes to allow any gas in the combustion
chamber to vent. Then if you smell gas, STOP!
Follow Step 1 in the Warning above. If you do not
smell gas, continue with the next step.
6. If you do not smell gas, push the electronic on-off
switch to the ON position.
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the appliance does not turn on, turn the gas
control switch to OFF and contact a qualified
service technician for assistance.
Turning Off the Appliance
Vacation Shutdown
Set the thermostat to the desired room temperature while
you are away.
Complete Shutdown
1. Turn off power to the appliance.
2. Turn off the gas supply to the appliance.
3. Push the on-off switch to the OFF
position. Appliance will completely shut off.
4. Follow the procedure in the Instructions to the
Homeowner section above to resume normal
operation.
8