Dust or Grease Accumulation
Heavy accumulations of dust or grease can cause the
control to malfunction. Where dust or grease can be a
problem, provide covers for the control to limit
contamination.
Heat
Excessively high temperatures can damage the control.
Make sure the maximum ambient temperature at the
control does not exceed the rating of the control. If the
appliance operates at very high temperatures, use
insulation, shielding, and air circulation, as necessary, to
protect the control. Proper insulation or shielding should
be provided by the appliance manufacturer; verify proper
air circulation is maintained when the appliance is
installed.

INSTALLATION

When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a
hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury
or death.
Follow these warnings exactly:
1. Disconnect power supply before wiring to
prevent electrical shock or equipment damage.
2. To avoid dangerous accumulation of fuel gas,
turn off gas supply at the appliance service
valve before starting installation, and perform
Gas Leak Test after installation is complete.
3. Always install a sediment trap in gas supply line
to prevent contamination of gas control.
4. Do not force the on-off switch. Use only your
fingers to operate the on-off switch. Never use
any tools. If the electronic on-off switch does
not operate by hand, the gas control should be
replaced by a qualified service technician.
Force or attempted repair may result in fire or
explosion.
5. Gas will leak if installed backwards.
CAUTION
Equipment Damage Hazard.
Can burn out thermostat or transformer.
Applying a jumper across (or shorting) the valve
coil terminals, even temporarily, can burn out the
thermostat or transformer.
Follow the appliance manufacturers instructions if
available; otherwise use these instructions as a guide.
VR8215S,T TRADELINE DIRECT IGNITION COMBINATION GAS CONTROLS
IMPORTANT
Converting Gas Control from
Natural Gas to LP Gas (or LP Gas
to Natural Gas)
Controls with standard and slow-opening regulators
(model numbers with suffix S or T) can be converted from
one gas to the other with a conversion kit. See Table 4 for
the conversion kit part number.
3
These gas controls are shipped with protective
seals over the inlet and outlet tappings. Do not
remove the seals until ready to install adapters
or connect the piping.
WARNING
Fire Or Explosion Hazard.
Can cause property damage, severe injury
or death.
1. Always change the main orifices when
converting from natural to LP gas or from LP to
natural gas. Carefully follow appliance
manufacturer specifications and instructions to
assure proper appliance conversion.
2. Gas controls are factory-set for natural (and
manufactured) or LP gas. Do not attempt to use
a gas control set for natural (manufactured) gas
on LP gas, or a gas control set for LP gas on
natural (manufactured) gas.
1. Turn off gas supply at the appliance service valve.
2. Remove regulator cap screw and save. See Fig. 5.
3. Remove the pressure regulator adjusting screw.
See Fig. 1.
4. Remove the existing spring.
5. Insert the replacement spring. See Fig. 1.
6. Install the new plastic pressure regulator adjust-
ment screw.
7. Check the regulator setting using a manometer or
by clocking the gas meter. See "Check and Adjust
Gas Input and Burner Ignition" on page 6.
8. Reinstall the regulator cap screw.
9. Mount conversion label on the gas control.
1
1
REUSE EXISTING METAL CAP SCREW.
Fig. 1. Converting between LP and natural gas.
COLOR CODE FOR
LP
NATURAL
GAS
GAS
PRESSURE
REGULATOR
BLACK
BLACK
ADJUSTING
SCREW
STAINLESS
RED
SPRING
STEEL
PRESSURE
REGULATOR
HOUSING
M20046B