SIEMENS AG

mb_setbit

The function mb_setbit sets a flag in the PLC to 1. It is not checked whether
the flag bit exists in the used PLC.
If there were no errors, the function supplies 0 as the return value otherwise an
error message which can be evaluated in accordance with the error table (see
error_message).
See also mb_setbit, mb_bittest
C-Adapter
int
mb_setbit (int mbno,int bitno);