Carrier ComfortLink 30HXC106 Installation Instructions Manual page 28

Fluid-cooled and condenserless chillers
Hide thumbs Also See for ComfortLink 30HXC106:

Advertisement

UNIT VOLTAGE
Supplied
UNIT
V-Hz
30HXA
(3 Ph)
Min
230-60
207
208/230-60
187
460-60
414
076
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
086
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
096
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
106
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
116
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
126
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
136
575-60
518
380-60
342
380/415-50
342
230-50
207
230-60
207
208/230-60
187
460-60
414
146
575-60
518
380-60
342
380/415-50
342
230-50
207
FLA
— Full Load Amps
ICF
— Maximum Instantaneous Current Flow during start-up (the
point in the starting sequence where the sum of the LRA for the
start-up compressor, plus the total RLA for all running com-
pressors, plus the total FLA for all running fan motors is at a
maximum)
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Ampacity (for wire sizing)
MOCP — Maximum Overcurrent Protection
RLA
— Rated Load Amps
WD
— Wye-Delta Start
XL
— Across-the-Line Start
*Units with one MCA, MOCP , and fuse size value have one terminal block and
require one power supply. Units with two MCA, MOCP , and fuse values have
2 terminal blocks.
†Wye-delta start is standard. Not available in across-the-line start.
NOTES:
1. Main power must be supplied from a field-supplied fused electrical service
with a (factory- or field-installed) disconnect located in sight from the unit.
2. Control circuit power must be supplied from a separate source through a
field-supplied disconnect (except for 380/415-50 units). An accessory con-
trol transformer may be used to provide control circuit power from the main
unit power supply.
3. Maximum incoming wire size for each terminal block is 500 kcmil.
4. Maximum allowable phase imbalance is: voltage, 2%; amps, 5%.
5. Use copper conductors only.
Table 4B — Electrical Data, 30HXA Units
Power
No. of
Supply
Power Supply
Qty
Conductors
Max
Req'd
Req'd
253
1
3
253
1
3
506
1
3
633
1
3
418
1
3
440
1
3
253
1
3
253
1
3
253
1
3
506
1
3
633
1
3
418
1
3
440
1
3
253
1
3
253
1
3
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
440
1
3
253
1
6
LEGEND
POWER CIRCUIT*
ICF
MCA
MOCP
XL
WD
291.2
400
436.4
323.6
450
450.8
146.0
200
549.9
217.9
116.8
150
439.9
174.9
177.1
250
614.7
247.7
183.4
250
686.5
272.5
303.3
400
439.8
322.8
450
496.4
358.7
500
510.8
161.9
225
644.9
247.9
129.5
175
535.9
198.9
196.2
250
719.7
281.7
205.5
300
796.5
307.5
339.7
500
495.8
365.4
500
562.4
406.1
600
576.8
183.4
250
749.9
280.9
146.5
200
599.9
224.9
221.1
300
835.7
317.7
231.4
350
937.5
351.5
382.6
500
566.8
416.9
600
647.4
463.2
700
661.8
209.2
300
884.9
323.9
167.2
250
707.9
258.9
253.3
350
984.7
364.7
263.3
400
1041.5
384.5
435.1
600
619.8
442.1
600
672.7
491.3
700
689.9
221.9
300
897.6
336.6
177.4
250
718.1
269.1
268.6
400
1000.0
380.0
281.0
400
1059.2
402.2
464.2
700
648.9
476.3
700
706.8
529.2
700
727.8
239.1
350
914.8
353.8
191.0
250
731.7
282.7
289.3
400
1020.7
400.7
301.7
400
1079.9
422.9
498.5
700
683.2
539.1
800
769.8
599.1
800
790.8
270.7
400
1014.8
385.8
216.2
300
811.7
308.7
327.5
450
1131.7
435.7
343.4
500
1345.9
506.9
567.3
800
817.2
580.3
800
811.0
644.8
800
836.5
291.3
400
1035.4
406.4
232.7
300
828.2
325.2
352.5
500
1156.7
460.7
358.9
500
1371.4
532.4
609.3
800
859.2
6. The MOCP is calculated as follows:
MOCP = (2.25) (largest RLA) + the sum of the other RLAs. Size the fuse
one size down from the result. The RLAs are listed on the unit nameplate.
7. The recommended fuse size in amps (RFA) is calculated as follows:
RFA = (1.50) (largest RLA) + the sum of the other RLAs. Size the fuse one
size up from the result. The RLAs are listed on the unit nameplate.
Units have the following power wiring terminal blocks and parallel
conductors:
VOLTAGE
208/230
(Sizes 076-171)
208/230
(Sizes 186-271)
460
575
380
230 (Sizes 076-171)
230 (Sizes 186-271)
380/415
#
CONTROL CIRCUIT
Recommended
V-Hz
Fuse Size
(Single Ph)
350
115-60
400
115-60
175
115-60
150
115-60
200
230-60
225
230-50
350
230-50
400
115-60
450
115-60
200
115-60
150
115-60
225
230-60
250
230-50
400
230-50
450
115-60
500
115-60
225
115-60
175
115.60
300
230-60
300
230-50
450
230-50
500
115-60
600
115-60
250
115-60
200
115-60
300
230-60
300
230-50
500
230-50
500
115-60
600
115-60
300
115-60
225
115-60
350
230-60
350
230-50
600
230-50
600
115-60
600
115-60
300
115-60
225
115-60
350
230-60
350
230-50
600
230-50
700
115-60
700
115-60
350
115-60
250
115-60
400
230-60
300
230-50
700
230-50
700
115-60
800
115-60
350
115-60
300
115-60
400
230-60
450
230-50
700
230-50
TERMINAL BLOCKS
OR NON-FUSED
DISCONNECTS
1
2
1
1
1
1
2
1
Supplied
MCA
and
Min
Max
MOCP
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
104
127
15
104
127
15
104
127
15
104
127
15
207
254
15
198
254
15
207
254
15
CONDUCTORS
6
6
3
3
3
6
6
3