10.2 Output Circuit
Rated Output Voltage
Maximum Output Current
Output Driver
On-State Resistance (average) : 23.5 Ω or less
Two types of wiring are available for use with the nonpolar photoMOS relay in the output
circuit.
Typical Output Circuit Application 1
RC180 Rev.17
: +12 V to 24 V ±10%
: TYP 100 mA/1 output
: PhotoMOS Relay
I/O-1
10 Output No.0
11 Output No.1
(Same)
12 Output No.2
(Same)
13 Output No.3
(Same)
14 Output No.4
(Same)
15 Output No.5
(Same)
27 Output No.6
(Same)
28 Output No.7
17 Output No.0 to 7 common (GND)
(Same)
29 Output No.8
(Same)
30 Output No.9
(Same)
Omit
33 Output No.8 to 15 common (GND)
Setup & Operation 10. I/O Connector
GND
+DC
L
Load
L
61