Output Circuit - Epson RC180 Manual

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

10.2 Output Circuit

Rated Output Voltage
Maximum Output Current
Output Driver
On-State Resistance (average) : 23.5 Ω or less
Two types of wiring are available for use with the nonpolar photoMOS relay in the output
circuit.
Typical Output Circuit Application 1
RC180 Rev.17
: +12 V to 24 V ±10%
: TYP 100 mA/1 output
: PhotoMOS Relay
I/O-1
10 Output No.0
11 Output No.1
(Same)
12 Output No.2
(Same)
13 Output No.3
(Same)
14 Output No.4
(Same)
15 Output No.5
(Same)
27 Output No.6
(Same)
28 Output No.7
17 Output No.0 to 7 common (GND)
(Same)
29 Output No.8
(Same)
30 Output No.9
(Same)
Omit
33 Output No.8 to 15 common (GND)
Setup & Operation 10. I/O Connector
GND
+DC
L
Load
L
61