6 | Unit introduction

2 Unit introduction

2.1 Type introduction

BOSCH
Climate
Fig. 2 Type introduction drawing

2.2 Product introduction

Bosch Climate5000 modular air handling unit
manufactured by Bosch Thermal Technology(
Shandong) CO., Ltd. certified by ISO 9000
authorization, applies to strict design and manu-
facturing standard, meet any limits specified by
this manual, and is able to ensure the quality, and
its liability and flexibility of each type of air han-
dling unit. The unit can be connected to water
chiller and heat pumps, and is not suitable for
other applications not specified by the manual.
The manual includes all for correct installation
and commissioning information, and operating
and maintenance instructions of the unit.
Prior to operating and maintenance of the unit,
please carefully read the manual. Any work
described in the manual including installation,
commissioning and maintenance can only be
conducted by trained and qualified professional
technicians.
8736862495(2015/07)
5000
MAHU
P
Value Level: 1000~9000
Category: Climate
Brand
-
06 . 07
M
L
Internal Width=07×Modulus(100mm)
Internal Height=06×Modulus(100mm)
P: Series Professional
C: Series Comfort
can be extended...
Modular Air Handling Unit
Any damage and broken due to incorrect installa-
tion, operation, commissioning and maintenance,
because of failure to comply steps and instructions
specified by this manual shall be free of any
responsibilities of the manufacture.

2.3 Left/ right Hand pipe connection

( →Page 7, Fig. 3, Schematic diagram of distin-
guishing left and right type)
• For MAHU with Mono structure, Left or Right
Hand pipe connection is decided by judging the
relative position of Air Inlet to the Water pipe
position. (Air inlet is Left to the water pipe
position, or Right to the water pipe position).
• For MAHU with double deck or side by side
structure, Left or Right Hand pipe connection is
decided by judging the relative position of Air Inlet
to the water pipe position of the single Mono part
which contain Coil Section. See below graph.
As default, the access door is on the same side as
pipe connection.
E
Export(Out of CN)
Pipe connection:
L= Left Hand, R=Right Hand
Type of structure:
M=Mono
S=Side by side
D=Double deck
Climate 5000