Toshiba RAS-18PKVSG-E Service Manual page 109

Hide thumbs Also See for RAS-18PKVSG-E:
Table of Contents

Advertisement

No.
Part name
5
Fan motor
6
Horizontal louver
7
Drain hose
Procedures
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
Cross flow fan
3.5 mm
Set screw
3) Remove 2 fixing screws of the motor band.
4) Pull the motor band and the fan motor
outward.
<To re-installation>
- Keep connector position and arrange fan
motor wire follow figure.
Fan motor wire
1) Remove shaft of the horizontal louver
from the back body. (First remove 2 the
center shafts then remove the other shafts.)
1) Follow the procedure item 3 .
2) The drain hose can be removed by removing
the screw securing the drain hose and then
pulling out the drain hose.
3) When removing the drain hose, be careful of
any sharp edges of steel plate. The edges can
injuries.
Heat insulator
Drain pan
of drain pan
Steel plate
of drain hose
<To re-installation>
- To install the drain hose, insert the drain hose
firmly until the connection part contacts with
heat insulator, and then secure it with original
screw.
Body back
Fan motor
Fan motor
connector
Drain hose
Screw
- 108 -
FILE NO. SVM-17001
Remarks
Cross flow fan
Vertical louver
Hexagon screw driver
Screws
Fan motor
Drain pan
Horizontal louver
Drain pan
Drain hose
Motor band