MD34030 $MA_REFP_MAX_CAM_DIST = corresponds to max. distance traversed
MD34040 $MA_REFP_VELO_SEARCH_MARKER =
MD34050 $MA_REFP_SEARCH_MARKER_REVERSE = e.g. FALSE
MD34060 $MA_REFP_MAX_MARKER_DIST = Difference betw. cam edge and 0 mark
MD34070 $MA_REFP_VELO_POS =
MD34080 $MA_REFP_MOVE_DIST = 0
MD34090 $MA_REFP_MOVE_DIST_CORR = 0
MD34092 $MA_REFP_CAM_SHIFT = 0
MD34100 $MA_REFP_SET_POS = 0
MD34200 $MA_ENC_REFP_MODE = 1
The reference point machine data (for the first encoder) of axis 3 must be specified
analogously.
2.7.2

Setting of NCK PLC interface

Introduction
An automatic synchronization process during axis referencing must be disabled initially so as
to prevent any damage to grouping axes that are misaligned.
Disabling of automatic synchronization
The PLC user program sets the following for the axis data block of axis 1:
DB31, ... DBX29.4 = 0
DB31, ... DBX29.5 = 1
The NCK sets the following as a confirmation in the axis block of axis 1:
DB31, ... DBB101: