The sign (S) of the analog value is always in bit number 15:
• "0" → +
• "1" → –
Measurement resolution
The following table shows the representation of the binary analog values and the
corresponding decimal and hexadecimal representation of the units of the analog values.
The table shows the resolutions 11, 12, 13, and 15 bit + sign. Each analog value is entered
left aligned in the ACCU. The bits marked with "x" are set to "0".
Table 4-3
Measured Value Resolution of the Analog Values (SIMATIC S7 Format)
Resolution in Bits
11+S
12+S
13+S
15 + sign
Note
This resolution does not apply to temperature values. The converted temperature values are
the result of a conversion in the analog electronics module.
Note
The following applies with temperature measurements: When leaving the linearized nominal
range, the existing gradient of the characteristic curve is retained in the overflow and
underflow range.
ET 200S
Manual, Edition 10/2005, A5E00514527-01
Units
Decimal
Hexadecimal
16
10
H
8
8
H
4
4
H
1
1
H
Analog electronic modules
4.2 Analog value representation
Analog Value
High byte
S 0 0 0 0 0 0 0
S 0 0 0 0 0 0 0
S 0 0 0 0 0 0 0
S 0 0 0 0 0 0 0
Low byte
0 0 1 x x x x
0 0 0 1 x x x
0 0 0 0 1 x x
0 0 0 0 0 0 1
4-3