Requirements Analysis - HP FlexFabric 5700 Series Configuration Manual

Fcoe configuration
Hide thumbs Also See for FlexFabric 5700 Series:
Table of Contents

Advertisement

Figure 35 Network diagram
Switch A
FCF switch
XGE1/0/5 to XGE1/0/8
XGE1/0/5 to XGE1/0/8
Switch C
FCF switch

Requirements analysis

To meet the network requirements, perform the following tasks:
To transmit the storage traffic over lossless Ethernet links in the SANs, HP recommends that you
perform the following tasks:
Configure DCBX, PFC in auto mode, and ETS on the Ethernet interfaces connecting the switches
to the server.
Configure DCBX and PFC in auto mode on the Ethernet interfaces connecting the switches to the
disk device.
Enable PFC by force on the Ethernet interfaces connecting switches.
To implement link backup between the server and the disk device, use two separate SANs to
provide connections between the server and the disk device. The two SANs can use the same
VSAN. The two separate VSANs are as follows:
One physical SAN is formed by the server, Switch A, Switch C, and the disk device.
The other physical SAN is formed by the server, Switch B, Switch D, and the disk device.
To transmit the Ethernet traffic of the LAN in VLAN 1001, configure the following interfaces to allow
VLAN 1001:
The Ethernet interfaces connecting Switch A and Switch B to the LAN.
The Ethernet interfaces connecting Switch A and Switch B to the server.
XGE1/0/10
VFC1
XGE1/0/1
VFC10
VFC10
VFC1
XGE1/0/1
LAN
Ethernet
switch
XGE1/0/10
VFC1
XGE1/0/1
Server
VFC1
XGE1/0/1
Disk device
130
Switch B
FCF switch
VFC10
XGE1/0/5 to XGE1/0/8
VFC10
XGE1/0/5 to XGE1/0/8
Switch D
FCF switch
Ethernet link
FCoE link