3. Setup

AC Power

Each Ovation ED-200WW has an auto-ranging power supply that works with an input voltage range of 100
to 240 VAC, 50/60 Hz. To determine the power requirements for each Ovation ED-200WW, refer to the
label affixed to the product. You can also refer to the
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com.
• Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the
product has an appropriate electrical ground to avoid the risk of electrocution or fire.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The Ovation ED-200WW comes with a power input cord terminated with a Neutrik® powerCON® on one
end and an Edison plug on the other end (U.S. market). If the power input cord that came with your product
has no plug, or if you need the change the plug, use the table below to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground

Power Linking

The product supports power linking.
In 750 W mode, you can link up to 6 Ovation ED-200WW products at 120 V, or 12 products at 230 V.
In 575 W mode, you can link up to 8 products at 120 V, or 15 products at 230 V.
This product comes with a power input cord. Power linking cables are available from Chauvet for purchase.

Fuse Replacement

1.
Disconnect the product from the power outlet.
2.
Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse and replace with another fuse of the same type and rating
(T 6.3 A, 250 V).
4.
Screw the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product from power before replacing a blown fuse.
Always replace the blown fuse with another of the same type and rating.
Page 6 of 28
Technical Specifications
Wire (U.S.)
Black
White
Green/Yellow
chart in this manual.
Wire (Europe)
Brown
Blue
Green/Yellow
Ovation ED-200WW User Manual Rev. 1
Setup
Screw Color
Yellow or Brass
Silver
Green