Broan ZB110HL Installation Manual page 5

X2, multi-speed ventilation fan with light, night light and humidity senson
Hide thumbs Also See for ZB110HL:

Advertisement

Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Fan
WHT
BLK
120 VAC
LINE IN
GRD
MANUAL-ON
SENSOR/CONTROL
BLACK
WHITE
ORANGE
MANUAL - ON
SENSOR / CONTROL
MASTER
MULTI-FUNCTION
WALL CONTROLS
(purchase separately)
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
MULTI-FUNCTION
WALL SWITCHES
LIGHT
NIGHT
LIGHT
MASTER
RED
GROUND
(green or bare)
BLUE
BROWN
SWITCH
BOX
LIGHT
NIGHT
LIGHT
120 VAC
LINE IN
WHT
BLK
RED
14/3
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED
BLU
BLK
WHT
GRD
LIGHT RECEPTACLE WIRES
RECEPTACLES
KNOCKOUT
PLATE
FAN RECEPTACLE
WIRES
ZB110HL Installation Guide
3
4
Screw from
Parts Bag
WHT
BLU
LIGHT
RED
NIGHT
LIGHT
SENSOR/
CONTROL
BLK
FAN
BLK
WHT
• MANUAL-ON switch is not required
to manually increase fan operation to
certified airflow rate (see page 10).
• MASTER and SENSOR/CONTROL
switches can be combined (see page
10).
• MASTER switch along with or
separate from SENSOR/CONTROL
switch may be located where they
are not easily accessed for everyday
usage, they may need to be labeled
and located where they can't be
turned on without being seen from
fan to comply with local and national
codes.
• See OPERATION
section on page 12 for
details.
• MASTER switch
turns fan system on
and shuts it off for
fan cleaning and
maintenance purposes.
• SENSOR/CONTROL
switch turns humidity
control automatic
operation on/off.
• MANUAL-ON switch
directly increases fan
operation to certified
airflow rate.
• MASTER switch must
be on for humidity
control or MANUAL-ON
switch to change fan
operation to certified
airflow rate.