Download Print this page
Hide thumbs Also See for Pro-Series:

Advertisement

Quick Links

Pro-Series Inserts
User Guide
[
Applicable for the following units:
CI2600 & HI400
Pro-Series wood burning is a
diff erent technology compared to
regular non-catalytic inserts. With
their new hybrid technology Pro-
Series units are highly effi cient,
long burning appliances.
Understanding the Pro-Series
technology and recommended
wood burning process will help
you
achieve
extended
times and use less wood over the
heating season.
TECHNOLOGY
Regency Pro-Series units run on
a hybrid catalytic system called
Eco-Boost™ technology. This hybrid
system allows the fuel to burn at a
slower rate utilizing its full potential.
Eco-Boost™
Hybrid System
Secondary Air Tube
Cleans up the emissions in the air
from the initial burn resulting in a
high heat output.
bypass closed; located inside firebox (top front)
Catalytic Combustor
Creates consistent heat by slowly
re-burning wood smoke particles
that would normally go up
the chimney.
LONG BURNING PROCEDURES
To obtain maximum burn times between 10 – 14 hours, it is important to have
the firebox and catalyst up to temperature (beyond 500º F, 260º C), after the
firebox is fully loaded. Only then should the bypass damper and draft control be
closed for the long burn.
• START UP PROCEDURE
1) Before starting a fire, open the bypass
damper, and fully open the draft control.
burn
3) Allow the fire to build, adding kindling
until the fire has a hold. After 5-10 minutes
add medium sized logs, after a further 5-
10 minutes close the door.
5)
• CONTINUOUS OPERATION PROCEDURE
1) With the unit and chimney now up to
operational temperature the reloading
process will require less time. At the end
of the burn cycle and to restart the unit,
open the door and spread the coals out
with a poker.
Always leave a minimum 1-2 inches of ash. This will insulate the fi rebox base and
maintain a higher temperature bed of hot coals and embers for a cleaner, longer burn.
BYPASS
OPEN
DRAFT
CONTROL
OPEN
2) Using dry kindling and rolled newspa-
per, build a fire base as normal, and ignite
leaving the door slightly open.
BYPASS
OPEN
DRAFT
CONTROL
OPEN
4) Once the fire becomes established
add large logs to the firebox until it is
fully loaded. Typically, after 20-30 minutes
you should be able to close the bypass
damper as temperatures will have
BYPASS
reached the "active" zone (beyond 500º F,
CLOSED
260º C).
5) Adjust the draft control for desired
DRAFT
burn rate.
CONTROL
to your
desire
+
-
BYPASS
CLOSED
DRAFT
CONTROL
OPEN
2) Then add some kindling or medium
sized logs. The wood will light up almost
immediately. Follow from STEP 4 above
to get your fi re back up and fi rebox fully
loaded, for your next long burn.
BYPASS
OPEN
DRAFT
CONTROL
OPEN
BYPASS
CLOSED
DRAFT
CONTROL
OPEN
BYPASS
CLOSED
DRAFT
CONTROL
OPEN

Advertisement

loading

Summary of Contents for Regency Pro-Series

  • Page 1 User Guide • START UP PROCEDURE BYPASS BYPASS Applicable for the following units: OPEN OPEN CI2600 & HI400 Pro-Series wood burning is a DRAFT DRAFT diff erent technology compared to CONTROL CONTROL OPEN OPEN regular non-catalytic inserts. With their new hybrid technology Pro- Series units are highly effi...
  • Page 2: Draft Control

    • Use soft wood for Kindling and Medium split logs for a fast burn • Use seasoned hard wood Large logs for a long burn Represents approximately (moisture content should be 20% or less) 1/2 full load for a Pro-Series insert Kindling Medium Large...