FAILURE DIAGNOSIS

(2) P0643/3: Failure with SENSOR 5V (High Voltage)

DTC
P0643/3
DTC Detecting Conditions
1 - Precondition; 2 - Detecting condition(s); 3 - Flashing pattern of failure indicator
1. Key switch ON.
2. SENSOR 5V monitoring voltage 5.5 [V] or higher.
3. Two flashes followed by four flashes.
Movement at Error occurrence
Error Mode
[Run As Is]:After detecting the error, the system lets the engine continue to run
without any restrictions.
Run restricted?
No.
Recovery
No.
Conditions
Remarks
Estimation of Failure cause/Error condition
• Wiring defect of the harness
The SENSOR GND wire may be disconnected.
The SENSOR 5V wire may be short-circuited with POWER SUPPLY.
• The E-ECU internal circuitry may be faulty.
Diagnosis Description
1) Initial diagnosis
with the diagnosis
tool
2) Check of
connectors/wiring
3) Failure Diagnostic
Work
1-54
DTCs (Diagnostic Trouble Codes) General Description
• Check the fault indication.
• Check the voltage of the Sensor 5V .
*For details of the method and the procedure of diagnosis, see P.1-160
• Before beginning your work, be sure to turn off the key switch.
• Check that the Sensor 5V line and sensor GND line are not disconnected or the
insulation of the wiring is not peeled.
• Check the harness for correct continuity.
• Check the output voltage of the E-ECU (voltage of the sensor 5V line).
*For details of the method and the procedure of diagnosis, see P.1-160
Failure with SENSOR 5V (High Voltage)
TNV DI Service Manual
Check points
Harness
E-ECU