P0223/3: Spare Accelerator Sensor Error (High Voltage) - Yanmar 3TNV82A Troubleshooting Manual

Electronic control
Hide thumbs Also See for 3TNV82A:
Table of Contents

Advertisement

FAILURE DIAGNOSIS

(2) P0223/3: Spare Accelerator Sensor Error (High Voltage)

DTC
P0223/3
DTC Detecting Conditions
1 - Precondition; 2 - Detecting condition(s);
3 - Flashing pattern of failure indicator
1. Key switch ON.
2. Sensor voltage 4.6 [V] or higher.
3. One flash followed by eight flashes
Movement at Error occurrence
Error Mode
[Run As Is]:
The engine continues to run using the
main accelerator sensor.
Run restricted?
No.
Recovery
Yes: This error will be automatically reset
Conditions
Remarks
Estimation of Failure cause/Error condition
• The connector may not be properly connected.
• Wiring defect of the harness
The SENSOR GND wire may be disconnected.
The sensor signal wire may be short-circuited with POWER SUPPLY.
• The spare accelerator sensor may be faulty.
Sensor output defect by a short circuit with power supply of the spare accelerator sensor inner wiring
• The E-ECU internal circuitry may be faulty.
1-24
DTCs (Diagnostic Trouble Codes) General Description
Error detection of main accelerator sensor
Unavailable
when a normal voltage (0.2 to
4.6[V]) is input.
Spare Accelerator Sensor Error (High Voltage)
Harness
Spare accelerator sensor
[Run Under Restrictions]:
The engine runs at a constant rotational
speed.
Yes: The target speed is set to the "on-
error target speed (standard value:
1500[min
speed".
Yes: This error will be automatically reset
when a normal voltage (0.2 to
4.6[V]) is input.
TNV DI Service Manual
Check points
Available
-1
])" or "pre-error target

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents