  • Page 2: Table Of Contents

     is sold or transferred. This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units  with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.
  • Page 3: Installing The Unit

    Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.  In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’ s ...
  • Page 4: Preparation For Outdoor Unit Installation

    Preparation for outdoor unit installation The air conditioner uses R-410A refrigerant. A Type: AC035HCADKH/ AC026HCADKH (Unit : mm)  Heat pump B Type: AC052HCADKH  Heat pump C Type: AC060HCADKH / AC071HCADKH / AC052HCAPKH  Heat pump...
  • Page 5 Moving the Outdoor Unit by Wire Rope Fasten the outdoor unit by two 8m or longer wire ropes as shown at the figure. To Wire rope prevent from damage or scratches, insert a piece of cloth between the outdoor unit and rope, then move the unit.
  • Page 6: Deciding On Where To Install The Outdoor Unit

    Air Guide Duct (This product is not Stereo provided by Samsung) 200mm  If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position.  Make sure that the water dripping from the drain hose runs away correctly and safely.
  • Page 7  When installing the outdoor unit near seashore, make sure it is not directly exposed to sea breeze. If you can not find a adequate place without direct see breeze, protection wall should be constructed.  Install the outdoor unit in a place (such as near buildings etc.) where it can be prevented from sea breeze which can damage the outdoor unit.
  • Page 8 Deciding on where to install the outdoor unit Space Requirements for Outdoor Unit When installing 1 outdoor unit  When the air outlet is opposite the wall  When the air outlet is towards the wall 2000 or more 300 or more 600 or more ...
  • Page 9 When installing more than 1 outdoor unit (Unit : mm)  When the air outlet is towards the wall 300 or more 600 or more 600 or more 600 or more  When 3 sides of the outdoor unit are blocked by the wall 300 or more 300 or more 600 or more...
  • Page 10: Outdoor Unit Installation

    Outdoor unit installation The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall or ground).
  • Page 11: Connecting The Cable

    220-240 20.0 20.0 22.7 22.7 25.0 AC052HCADKH AC052HBMDKH AC060HCADKH AC060HBMDKH 220-240 20.0 20.0 22.7 22.7 25.0 AC071HCADKH AC071HBLDKH 220-240 20.0 20.0 22.0 22.0 25.0 220-240 20.0 20.0 22.7 22.7 25.0 AC071HCADKH AC071HBMDKH 220-240 20.0 20.0 22.7 22.7 25.0 AC052HCAPKH AC052HBMPKH...
  • Page 12 Connecting the cable 1. Voltage range - Units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits 2. Maximum allowable voltage variation between phases is 2%. 3. Wire size & type must comply with the applicable local and national code. - Wire size : Based on the value of MCA.
  • Page 13 Wiring Diagram of Power Cable When using ELCB for 1 phase Power Supply Electrical component box MCCB 1(L) 2(N) MCCB Cable tie Indoor Power Cable clamp Main power cable Communication cable Indoor Unit  The appearance of the unit may be different from the picture depending on the model. •...
  • Page 14: Connecting The Power Terminal

    Connecting the cable Connecting the Power Terminal  Connect the cables to the terminal board using the compressed ring terminal.  Cover a solderless ring terminal and a connector part of the power cable and then connect it. Silver solder Nominal Nominal dimensions...
  • Page 15: Connecting The Refrigerant Pipe

    Connecting the refrigerant pipe Refrigerant piping system Maximum allowable lengh Items Single installation DPM installation AC026HCADKH AC052HCADKH AC060HCADKH Applicable outdoor unit models AC071HCADKH AC035HCADKH AC052HCAPKH AC071HCADKH Total pipe length (L1+…+Ln+1 +a+b) 50 m Main pipe (L1) 20 m 30 m 50 m 30 m Max.
  • Page 16: Adding Refrigerant (R-410A)

    Adding refrigerant (R-410A) The outdoor unit is loaded with sufficient refrigerant for the standard piping. Thus, refrigerant must be added if the piping is lengthened. This operation can only be performed by a qualified refrigeration specialist. For quantity of adding refrigerant, refer to page 17.
  • Page 17 How to Calculate the Quantity of Adding Refrigerant The quantity of additional refrigerant is variable according to the installation situation. Thus, make sure the outdoor unit situation before adding refrigerant. This operation can only be performed by a qualified refrigeration specialist. Single installation outdoor unit Interconnection pipe length (m) Model...
  • Page 18: Installing Dpm

    Installing DPM DPM allowable Outdoor and indoor unit models DPM allowable Outdoor and indoor unit models 2 indoor units connection Outdoor unit models Indoor unit AC071HCADKH AC035HBMDKH  Installation of multiple indoor units should consist of units that have the same capacity. Space requirements for indoor and outdoor units and piping installation (Refer to page 8~9 installation specification.) - Two indoor units should be installed in one area which is not divided by a wall.
  • Page 19 Connecting communication line and wired remote controller In case of 2 indoor units connection F1/F2 F1/F2 F1/F2 Outdoor Indoor unit #2 Indoor unit #1 unit Remote control  The wired remote controller can be used with any of the DPM indoor units. Operation and specification - The two, the three, or the four sets of the indoor units with DPM installation which are controlled by wired and wireless remote controller work equally.
  • Page 20: Connecting Up And Removing Air In The Circuit

    Connecting up and removing air in the circuit • When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high.
  • Page 21: Cutting/Flaring The Pipes

    Cutting/Flaring the pipes 1. Make sure that you have the required tools available. (pipe cutter, reamer, flaring tool and pipe holder) 2. If you wish to shorten the pipes, cut it with a pipe cutter, taking care to ensure that the cut edge remains at a 90° angle with the side of the pipe.
  • Page 22: Performing Leak Tests

    Performing leak tests LEAK TEST WITH NITROGEN (before opening valves) In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R-410A, it’s responsable of installer to pressurize the whole system with nitrogen (using a cylinder with pressure reducer) at a A(Gas) pressure above 40 bar (gauge).
  • Page 23: Insulation

    Insulation Once you have checked that there are no leaks in the system, you can insulate the piping and hose. 1. To avoid condensation problems, place an insulator around each refrigerant pipe. • When insulate the pipe, be sure to overlap the insulation. •...
  • Page 24: Using Stop Valve

    Using stop valve To Open the Stop Valve 1. Open the cap and turn the stop valve counterclockwise by using a hexagonal wrench. 2. Turn it until the axis is stopped. Service port • Do not apply excessive force to the stop valve and always use special instruments.
  • Page 25: Interface Module Installation (Optional)

    Interface module Installation (Optional) Accessories (Interface module : MIM-B13D) Interface module Interface module Interface module Installation Manual Case Cable-tie power cable communication cable 1. Fix the case at with bolts on the side of the control box in the outdoor unit. ✴026/035/052✴...
  • Page 26: Pump Down Procedure

    Pump down Procedure Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area. 1. Remove the cap from the low pressure side. 2. Turn the low pressure side valve clockwise to close and connect a pressure gauge (low pressure side) to the service valve, and open the valve again.
  • Page 27: Checking Correct Grounding

    Checking correct grounding If the power distribution circuit does not have a grounding or the grounding does not comply with specifications, an grounding electrode must be installed. The corresponding accessories are not supplied with the air conditioner. 1. Select an grounding electrode that complies with the specifications given in the illustration.
  • Page 28: Testing Operations

    Testing operations 1. Check the power supply between the outdoor unit and the auxiliary circuit breaker.  1 phase power supply : L, N 2. Check the indoor unit. 1) Check that you have connected the power and communication cables correctly. (If the power cable and communication cables one mixed up or connected incorrectly, the PCB will be damaged.) 2) Check the thermistor sensor, drain pump/hose, and display are connected correctly.
  • Page 29 6. View Mode : When the K4 switch is pressed, you can see information about our system state as below. Short push Display contents SEG1 SEG2 SEG3 SEG4 Unit Order frequency Hundreds' digit Tens' digit Unit digit Current frequency Hundreds' digit Tens' digit Unit digit The number of current indoor units...
  • Page 30: Commission Delegated Regulation (Eu) No 626/2011

    COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ⁱⁱ) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. AC052HBLDKH AC071HBLDKH AC035HBMDKH Model name (Indoor/Outdoor) AC052HCADKH AC071HCADKH AC035HCADKH Sound Power Level (Inside/Outside)
  • Page 31 Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. AC052HBMDKH AC060HBMDKH AC071HBMDKH Model name (Indoor/Outdoor) AC052HCADKH AC060HCADKH AC071HCADKH Sound Power Level (Inside/Outside) dB(A) 53/63 57/64 57/65 Refrigerant name R-410A R-410A R-410A 2088 2088 2088 SEER...
  • Page 32 COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ⁱⁱ) Samsung Samsung Samsung Supplier's name Electronics Co., Ltd. Electronics Co., Ltd. Electronics Co., Ltd. AC052HBMPKH AC026HBLDKH AC035HBLDKH Model name (Indoor/Outdoor) AC052HCAPKH AC026HCADKH AC035HCADKH Sound Power Level (Inside/Outside) dB(A) 53/63 53/63...
  • Page 33 [NEDERLANDS-NL] [POLSKI-PL] Naam van de leverancier Nazwa dostawcy Modelnaam (binnen/buiten) Nazwa modelu (Wewnętrzny/zewnętrzny) Poziom mocy akustycznej (Wewnętrzna/ Geluidsniveau (binnen/buiten) zewnętrzna) Koelmiddel Nazwa środka chłodzącego SEER SEER Enegie-efficiencyklasse (SEER) Klasa energetyczna (SEER) (koelingsseizoen) (okres chłodzenia) Pdesignc Pdesignc SCOP SCOP Enegie-efficiencyklasse (SCOP) Klasa energetyczna (SCOP) (verwarmingsseizoen) (okres grzewczy)
  • Page 34 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [MAGYAR-HU] ČEŠTINA-CS Forgalmazó neve Název dodavatele Modellnév (Beltéri/kültéri) Název modelu (vnitřní/venkovní) Zajszint (Beltéri/kültéri) Hladina akustického výkonu (vnitřní/venkovní) Hűtőközeg neve Název chladiva SEER SEER Energiahatékonysági osztály (SEER) Třída energetické...
  • Page 35 [SLOVENČINA-SK] [ROMÂNĂ-RO] Názov dodávateľa Numele furnizorului Názov modelu(vnútorné/ Numele modelului (interior/exterior) vonkajšie) Hladina akustického výkonu (vnútorná/vonkajšia) Nivel de putere acustică (interior/exterior) Chladivo Numele agentului frigorific SEER SEER Trieda energetickej účinnosti (SEER) Clasă de eficiență energetică (SEER) (sezóna chladenia) (perioadă de răcire) Pdesignc Pdesignc SCOP...
  • Page 36 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [БЪЛГАРСКИ-BG] [SRPSKI-SR] Naziv dobavljača Име на доставчик Naziv modela (unutršnja jedinica/ Име на модел (вътрешно/външно тяло) spoljašnja jedinica) Ниво на акустична мощност (вътрешно/ Nivo buke (unutrašnja/spoljna jedinica) външно...
  • Page 37 [HRVATSKI-HR] [SHQIP-SQ] Naziv dobavljača Emri i ofruesit Naziv modela (unutarnji/spoljni) Emri i modelit (i brendshëm/jashtëm) Razina zvučne snage (u zatvorenom/ Niveli i fuqisë së zhurmës (brenda/jashtë) otvorenom) Naziv rashladnog sredstva Emri i ftohësit SEER SEER Razred energetske učinkovitosti (SEER) Kategoria e efikasitetit të energjisë (SEER) (sezona hlađenja) (stina e ftohjes) Pdesignc...
  • Page 38 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [МАКЕДОНСКИ-MK] [SLOVENČINA-SL] Име на испорачувач Názov dodávateľa Názov modelu(vnútorné/ Име на модел (внатрешен/надворешен) vonkajšie) Hladina akustického výkonu (vnútorná/ Ниво на јачина на звук (внатре/надвор) vonkajšia) Име...
  • Page 39 [DANSK-DA] [SVENSKA-SV] Leverandørens navn Leverantörens namn Modelnavn (indendørs/udendørs) Modellnamn (inomhus/utomhus) Lydeffektniveau (indenfor/udenfor) Ljudnivå (inomhus/utomhus) Navnet på køleelementet Köldmedium SEER SEER Energieffektivitetsklasse (SEER) Energieffektivitetsklass (SEER) (kølesæson) (kylningssäsong) Pdesignc Pdesignc SCOP SCOP Energieffektivitetsklasse (SCOP) Energieffektivitetsklass (SCOP) (varmesæson) (uppvärmningssäsong) Andre opvarmningssæsoner, der er beregnet Andra passande uppvämningssäsonger til brug Pdesignh (gennemsnitlig)
  • Page 40 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [SUOMI-FI] [EESTI-ET] Tavarantoimittajan nimi Tarnija nimi Mallin nimi (sisä/ulko) Mudeli nimi (sisetingimused/välistingimused) Helivõimsuse tase (sisetingimused/ Äänitehotaso (sisä/ulko) välistingimused) Kylmäaineen nimi Jahutusaine nimi SEER SEER Energiatehokkuusluokka (SEER) Energiatõhususe klass (SEER) (jäähdytyskausi) (jahutamishooaeg)
  • Page 41 [LIETUVIŲ KALBA-LT] [LATVIEŠU-LV] Piegādātāja nosaukums Tiekėjo pavadinimas Modelio pavadinimas (naudojamo patalpose / Modeļa nosaukums (iekštelpu/ārtelpu) lauke) Skaņas intensitātes līmenis (iekštelpu/ārtelpu) Garso galios lygis (patalpose / lauke) Aukstumaģenta nosaukums Šaldalo pavadinimas SEER SEER Energoefektivitātes klase (SEER) Energijos suvartojimo efektyvumo klasė (SEER) (dzesēšanas sezonā) (vėsinimo sezonas) Pdesignc...
  • Page 42 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [NEDERLANDS-NL] 1) Lekken van koelmiddel dragen bij tot de klimaatveranderingen. Koelmiddelen met een lager Global Warming Potential (GWP) dragen minder bij tot de klimaatveranderingen dan een koelmiddel met een hogere GWP, indien ze in de atmosfeer vrijkomen.
  • Page 43 [ČEŠTINA-CS] 1) Dopady úniků chladiva na klimatické změny. Chladivo s nižším potenciálem globálního oteplování (GWP) má v případě úniku do ovzduší menší vliv na globální oteplování než chladivo s vyšším GWP. Zařízení obsahuje chladicí kapalinu s GWP, který odpovídá hodnotě [2088]. To znamená, že když...
  • Page 44 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [Български-BG] 1) Течовете на хладилен агент допринасят за изменението на климата. Хладилен агент с по-нисък потенциал за глобално затопляне (GWP) би допринесъл по-малко за глобалното затопляне, отколкото...
  • Page 45 SHQIP-SQ 1) Rrjedhja e ftohësit ndikon në ndryshimin e klimës. Ftohësi me potencial më të ulët për ngrohje globale (GWP) do të ndikonte më pak në ngrohjen globale se ftohësit me GWP më të lartë, nëse rrjedh në atmosferë. Kjo pajisje përmban lëng ftohës me GWP të barabartë me [2088]. Kjo do të...
  • Page 46 ⁱ) COMMISSION DELEGATED REGULATION (EU) No 626/2011 ⁱⁱ) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) [DANSK-DA] 1) Udsivning fra køleelementet er medvirkende til klimaforandringerne. Køleelementer med et lavere globalt opvarmningspotentiale (GWP) bidrager mindre til den globale opvarmning end køleelementer med et højere GWP, hvis der er udsivning i atmosfæren.
  • Page 47 [EESTI-ET] 1) Jahutusaine lekkimine soodustab kliimamuutust. Väiksema globaalse soojenemise potentsiaaliga jahutusaine soodustab atmosfääri lekkimise korral globaalset soojenemist vähem kui suurema globaalse soojenemise potentsiaaliga jahutusaine. See seade sisaldab jahutusainet, mille globaalse soojenemise potentsiaal on [2088]. See tähendab, et kui 1 kg jahutusvedelikku lekiks atmosfääri, oleks selle mõju globaalsele soojenemisele 100 aasta jooksul [2088] korda suurem kui 1 kg CO2 lekkimise korral.
  • Page 48: Troubleshooting

    Troubleshooting The table below give indication about self diagnostic routine. Some of error code requires activities exclusively for Authorized Service Center. Outdoor unit If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. Meaning Remarks Error Code...
  • Page 49: Appendix

    Meaning Remarks Error Code 1. Check if the service valve is open 2. Check for refrigerant leakage (pipe connections, heat exchanger) and charge refrigerant if necessary 29 EEV or Valve Close error-Self diagnosis E422 3. Check if there's any blockage on refrigerant cycle (indoor unit/outdoor unit) 4.
  • Page 50: How To Connect Your Extended Power Cables

    How to connect your extended power cables 1. Prepare a compressor and the following tools. Connection sleeve Tools Crimping pliers Insulation tape Contraction tube (mm) (mm) Spec MH-14 20xØ6.5(HxOD) Width 19mm 70xØ8.0(LxOD) Shape 2. As shown in the figure, peel off the shields from the rubber or wire of the Power cable (provided by power cable.
  • Page 51 5. Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape. A total of three or more layers of insulation is required. f Method 1 f Method 2 Insulation tape Insulation tape 40 mm 35 mm...
  • Page 52 SAMSUNG ELECTRONICS CO.,LTD. No.501,Suhong East Road,Suzhou Industrial Park,Jiangsu Province,P.R.China Samsung Electronics (UK) Ltd, Euro QA Lab. Blackbushe Business Park. Saxony Way, Yateley, Hampshire. GU46 6GG United Kingdom...
  • Page 53: Air Conditioner

    AC✴✴✴HCADKH AC✴✴✴HCAPKH Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR IT PT DE EL DB68-04465A-10...