4. Commissioning
If the DeviceNet option has been fitted cor-
rectly into the flowmeter, the menu structure
will show a new group of parameters:
DeviceNet module
This group of parameters will be explained in
detail in this chapter.
Mac ID (MAC ID)
Selection
0 - 63
Function
Every station connected to the same bus must
have an unique address. The address can only
be set by using the keypay display or via
explicit messaging.
Baud rate (Baud rate)
Value
125 K baud
250 K baud
500 K baud
Function
Selection of the DeviceNet transmission
speed. It must correspond to the transmission
speed of the master and the other DeviceNet
nodes.
Assembly selection (POLL set)
Value
Assembly selection 1/2
Assembly selection 100/2
Assembly selection 101/2
Assembly selection 102/2
Assembly selection 103/2
Assembly selection 104/2
Assembly selection 105/2
Function
Assembly selection parameter changes the
active I/O assembly instance of the Bus module.
If the Bus module is installed in a MAG 6000,
only selection 1 and 2 are possible.
Changes to this parameter takes effect imme-
diately. Use with care on a running system.
Description of the selection MAG 6000
• Assembly selection 0: 1 Word for control of
the MAG 6000, 6 words for feed back
• Assembly selection 1: 1 Word for control of
the MAG 6000, 7 words for feed back
SFIDK.PS.023.C2.02
Description of the selection MASS 6000
• Assembly selection 1/2: 1 Word for control
of the MASS 6000, 6 words for feed back
• Assembly selection 100/2: 1 Word for con-
trol of the MASS 6000, 5 words for feed back
• Assembly selection 101/2: 1 Word for con-
trol of the MASS 6000, 7 words for feed back
• Assembly selection 102/2: 1 Word for con-
trol of the MASS 6000, 9 words for feed back
• Assembly selection 103/2: 1 Word for con-
63
trol of the MASS 6000, 11 words for feed back
• Assembly selection 104/2: 1 Word for con-
trol of the MASS 6000, 15 words for feed back
• Assembly selection 105/2: 1 Word for con-
trol of the MASS 6000, 9 words for feed back
DeviceNet software version
(DeviceNet SW version)
Value
(125 K baud)
(250 K baud)
No control panel access
(500 K baud)
Communication status (Comm status)
Value
No control panel access
Update rate of measured values
(Update rate)
Value
2 Hz
[POLL set 0]
10 Hz
[POLL set 1]
[POLL set 2]
Function
[POLL set 3]
This function is only implemented in the MASS
[POLL set 4]
6000. When using this parameter the user can
[POLL set 5]
determine how often the MASS 6000 transmits
new values of the mass flow to the DeviceNet
[POLL set 6]
Bus module.
Enter programming mode (Enter Prog mode ?)
Value
No
Yes
Function
This function sets the DeviceNet option into a
special mode where it is possible to reprogram
the firmware of the DeviceNet option through
the DeviceNet Bus module.