Toshiba FT-8259 Service Manual page 7

Cordless phone
Table of Contents

Advertisement

Receiver Section
Connections
Preset
a) Connect the handset RF unit to the handset main unit.
b) Connect DC power supply to battery connector on the handset unit.
c) Turn the DC power supply ON while pressing " * " and " # " keys, and keep pressing the keys continuously for
approximate 1 second.
d) Release keys when entering TEST mode 1 with TALK LED and LINE2 LED lighting and beep.
Alignment Procedure
step
Preset to
Adjustment
SG: 1mV
1
(Discriminator
No modulation
SG: 1mV
1 kHz ±8kHz
2
deviation
SG: -7.0 dBµ µ µ µ µ V
1kHz ±8kHz
3
(SQ Point)
Deviation
Alignment Point Location on Handset Main PCB and Handset RF PCB
Handset PCB
HANDSET Unit
RF SG
RF
-
Test Point
+
DC Power Supply
J603
Battery
Connector
DC 3.8V
Press the "4" key to enter the TEST Mode 4. Connect the RF Singal
L603
Generator to the RF test point on the handset MAIN PCB. Make sure that
the frequency is 926.997467 MHz.
Voltage)
Connect the DC Voltmeter to the AF test point. Adjust L603 to indicate
DC 0.85V.
Connect the RF Signal Generator to the RF test point on the handset MAIN
RT602
PCB. Make sure that the frequency is 926.997467 MHz.
(RX AF
Connect the AC Voltmeter across a 150-ohm dummy to the SP Connector.
Voltage)
Adjust RT602 for a 150 mV reading on the AC Voltmeter.
Press the "5" key to enter the TEST Mode 5. Make sure that the frequency
RT601
of RF SG output is 926.997467 MHz. Adjust RT601 to turn to the point
where the LINE1 LED just turns on.
Dummy Load
(150-ohm)
SP
-
Terminal
+
DC Voltmeter
AF
Test Point
Remarks
AF Test Point
RF PCB
6
AC Voltmeter
RF Test Point

Advertisement