Trouble code
2.3.7

C0BA0:Elevator Motor (M7-FN) drive malfunctions

A. Detection timing
Malfunction code
The Elevator Tray Upper Limit Sensor PQ (PWB-D FN) is not activated even after
the lapse of a given period of time after M7-FN has been energized (to start raising
the Elevator Tray).
C0BA0
The Elevator Tray Upper Limit Switch (S2-FN) or Elevator Tray Lower Limit Switch
(S3-FN) is actuated after M7-FN has been energized.
B. Action
Elevator Tray Upper Limit Sensor PQ (PWB-D FN)
Elevator Tray Upper Limit Switch (S2-FN)
Elevator Tray Lower Limit Switch (S3-FN)
Elevator Motor (M7-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PWB-D FN I/O, sensor check
4
S2-FN operation check
5
S3-FN operation check
6
M7-FN operation check
7
PWB-A FN replacement
4-14
Relevant electrical parts
Action
FS-501 Field Service Ver2.0 Sep. 2004
Description
Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
-
-
PWB-A FN PJ21A FN-2,4
PWB-A FN PJ18A FN-4
PWB-A FN PJ16A FN-4
PWB-A FN PJ5A FN-1,2
-