Contents
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection and Maintenance Schedules
Parts Ordering
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Latest Published Instruction Manual
Introduction
The product covered in this document is Inactive. This document, which includes the latest published version of the
instruction manual, is made available to provide updates of newer safety procedures. Be sure to follow the safety
procedures in this supplement as well as the specific instructions in the included instruction manual.
Part numbers in the included instruction manual should not be relied on to order replacement parts. For replacement
parts, contact your
Emerson sales office
For more than 20 years, Fisher products have been manufactured with asbestos‐free components. The included
manual might mention asbestos containing parts. Since 1988, any gasket or packing which may have contained some
asbestos, has been replaced by a suitable non‐asbestos material. Replacement parts in other materials are available
from your sales office.
Safety Instructions
Please read these safety warnings, cautions, and instructions carefully before using the product.
These instructions cannot cover every installation and situation. Do not install, operate, or maintain this product
without being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance. To
avoid personal injury or property damage it is important to carefully read, understand, and follow all of the contents of
this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact
your Emerson sales office or Local Business Partner before proceeding.
www.Fisher.com
1
1
2
. . . . . . . . . . .
2
2
3
3
3
. . . . . . . . . . . . . .
5
or Local Business Partner.
585CLS Actuator
April 2018

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Fisher 585CLS

  • Page 1 If you have any questions about these instructions, contact your Emerson sales office or Local Business Partner before proceeding. www.Fisher.com...
  • Page 2 WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher product, because they may void your warranty, might adversely affect the performance of the product, and could cause personal injury and property damage.
  • Page 3 If you cannot determine the limits for this product, contact your Emerson Automation Solutions sales office before proceeding. D To avoid personal injury, always wear protective gloves, clothing, and eyewear when performing any installation operations.
  • Page 4 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co.
  • Page 5: Table Of Contents

    W2795-1 Introduction Scope of Manual This instruction manual provides information on installation, maintenance, and parts ordering for the Fisher 585CLS Long Stroke piston actuator. Refer to separate instruction manuals for information about other equipment and accessories used with these actuators.
  • Page 6: Specifications

    Specifications for 585CLS piston actuators are given in table 1. Some individual actuators come from the factory with specifications stamped on a nameplate attached to the yoke. Educational Services For information on available courses for Fisher 585CLS piston actuators, as well as a variety of other products, contact: Emerson Process Management Educational Services, Registration P.O.
  • Page 7 Pressure Connections diameter cylinder--13.8 bar (200 psig) unless limited Standard is 1/4 NPT. For larger sizes, consult your by maximum allowable supply pressure of positioner Emerson Process Management sales office or switching device Construction Materials Travel Information All Types: 229 mm (9 inches) through 610 mm (24...
  • Page 8: Installation

    20900 22400 1. For operating pressures above 10.3 bar (150 psig), consult your Emerson Process Management sales office. 2. For travels greater than 406 mm (16 inches) with 10.3 to 17.3 bar (150 to 250 psig) operating pressure. 3. For travels greater than 406mm (16 inches).
  • Page 9: Bypass Assembly

    Instruction Manual 585CLS Actuator D103793X012 October 2013 Check with your process or safety engineer for any additional measures that must be taken to protect against process media. If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance sections in this instruction manual.
  • Page 10: Three-Way Valve Applications Note

    Instruction Manual 585CLS Actuator D103793X012 October 2013 Three-Way Valve Applications Note WARNING To avoid loss of control of process fluid and subsequent personal injury or property damage caused by bursting of pressure-retaining parts, be sure the cylinder pressure does not exceed 80 psig in high cycle-rate, fast stroking speed, three-way valve applications.
  • Page 11: Maintenance

    Instruction Manual 585CLS Actuator D103793X012 October 2013 With the pointer (key 42) in the neutral position, automatic operation is possible throughout full travel. The locking pin (key 10) should be left out during automatic operation, and the needle valve (key 54) must be closed. For manual operation, the locking pin (key 10) must be inserted into the hole in the sleeve assembly before you open the needle valve (key 54).
  • Page 12: Handwheel Construction

    Instruction Manual 585CLS Actuator D103793X012 October 2013 1. Disconnect the cylinder tubing from the cylinder (key 11) and positioner. 2. Break the stem connection by loosening the two locknuts (key 23) and removing the four cap screws from the stem connector.
  • Page 13: Stem Connection Procedure

    Parts Ordering When corresponding with your Emerson Process Management sales office about this equipment, refer to the serial number found on the actuator nameplate (key 21). Also, specify the complete 11-character part number from the...
  • Page 14: Parts List

    October 2013 WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Process Management should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
  • Page 15 Instruction Manual 585CLS Actuator D103793X012 October 2013 Figure 2. Fisher 585CLS Actuator VIEW B-B BACK VIEW SECTION A-A LP-LUBRIPLATE NO. 130AA PACK PARTS 20 AND 40 WITH MULTIPURPOSE GREASE 52A7782-A...
  • Page 16 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, FIELDVUE, and TopWorx are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co.

Table of Contents