HP D3600 Maintenance And Service Manual page 37

Disk enclosure
Table of Contents

Advertisement

Error Type
Error Code
B6
B8
BE
SAS Cable
B9
Error
BA
Disk Drive
BB
Error
BC
Thermal
C0
Control Error
C1
C2
Thermal
C3
Shutdown
Alarms
C4
C5
C6
Error Detail
Recommended Action
Expander firmware
version mismatch with
Expander firmware
version in partner I/O
module
Expander firmware
image error
Expander firmware
version mismatch with
ESP firmware version in
own I/O module
SAS cable hardware
1. Verify the SAS cable status indicators. For the cables
error
Hewlett Packard
2. If the cables are properly connected and the error
Enterprise unsupported
SAS cable
3. If replacing the cables does not resolve the issue,
4. If there is no new firmware available, or upgrading
Error in disk drive
Check your storage administration software for more
information about the problem detected and how to
properly fix it.
Not authentic drive in
There is at least one non-authentic HPE disk drive on
the enclosure
the system. Non-authentic disks may not work properly
on this system.
Check your storage administration software for more
information about the problem detected and how to
properly fix it.
Generic temperature
1. Remove the module, wait 10 seconds, reinsert the
error
2. If the error persists, then check for new firmware
Permanent error in
temperature sensor I2C
bus
3. If the error persists, contact an Hewlett Packard
Error reading data from
temperature sensor
Warning temperature
Check for thermal issues, such as extremely hot drives,
reached in temperature
air blockages, missing or failed fans, or high ambient
sensor
temperature.
Critical temperature
reached in temperature
sensor
Minimum temperature
reached in temperature
sensor
Fans commanded to
maximum speed
with an amber LED (error), check if the cables are
properly connected in both sides.
persists, replace the cables.
then check for new firmware releases. A firmware
upgrade might fix the issue
the firmware is not possible, contact an Hewlett
Packard Enterprise representative. An I/O module
replacement may be necessary.
module.
releases and upgrade the enclosure firmware. New
firmware versions, containing new features and
defect fixes, are released periodically.
Enterprise representative. An I/O module
replacement may be necessary.