7: Troubleshooting
Table 7-1: Troubleshooting guide
Symptom
Liquid water in com-
pressed air lines
54
Probable cause
Plugged separator
Plugged strainer in moisture drain
line
Water vapor condensation from
cooling and compression occurs
naturally
Defective drain solenoid valve
Improper drain settings.
02250203-986 R03
Subject to EAR, ECCN EAR99 and related export control restrictions.
E900H User Manual
Remedy
Check separator differential.
Clean and service strainer located in
the line off the bottom of the water sep-
arator.
Remove the water vapor from com-
pressed air prior to distribution through
the air system. Check operation of
aftercooler and moisture separator.
Install a compressed air dryer sized for
the flow and dryness level required.
(Note: Filters may also be required to
remove particulates, liquid oil aerosols
or for oil vapor removal. Change car-
tridges as recommended by the filter
manufacturer). Check all drain traps
routinely to insure their proper opera-
tion. Maintain them regularly.
Ensure valve opens and closes as sig-
naled by timer.
Check drain interval and drain time,
and adjust accordingly. High humidity
conditions require longer drain times or
more frequent openings.