3: Specifications
3.2 Lubrication guide—compressor
Fluid type
® 1
Sullair AWF
®
Sullube
SAE 10W SE, SF, SG, CD
MIL-L-2104E 10W
1
Sullair part numbers for Sullair AWF are 250030-757 (5 gallons/18.9 liters) and 250030-758 (55 gallon drum/280 liters).
2
Models filled with long life Sullube lubricant should be changed under the following conditions, whichever occurs first:
• Every 8000 hours.
• Once a year.
• As indicated by fluid analysis. A fluid sample at every 1000 hours is recommended.
• For information about a free Sullube analysis, contact your Sullair representative.

3.3 Application guide

Sullair air compressors are supplied with Sullair AWF
which is a heavy duty multi-viscosity, all weather fluid
which provides an extended change interval when com-
pared to other fluids. Detergent motor oils (SAE 10W
Class SE, SF, SG, or CD) can also be used. Any of these
oils are suitable under conditions where severe oil oxida-
tion can occur.
Water must be drained from the separator tank periodi-
cally. In high ambient temperature and humidity condi-
tions, condensed moisture can emulsify with the oil
forming a "milky" color. SAE 10W is especially prone to
this condition. The fluid should be changed if this condi-
tion develops.
30
Change period/hours
®
02250203-986 R03
Subject to EAR, ECCN EAR99 and related export control restrictions.
Ambient temperature range °F (°C)
1500
2
varies
250
250
Do not mix different fluids. Combinations of different flu-
ids can lead to operational problems such as foaming,
plugged filters, blocked orifices or lines.
When ambient conditions exceed the recommended
ranges, or if other conditions warrant the use of other
extended life lubricants, contact your local Sullair repre-
sentative for recommendations.
Sullair encourages users to participate in a fluid analysis
program. The analysis might indicate a need for change
intervals different from those recommended in this man-
ual. Sullair offers a fluid analysis for Sullair AWF. Contact
Sullair for details.
E900H User Manual
-20 to 125 (-29 to 52)
32 to 125 (0 to 52)
0 to 100 (-18 to 38)
0 to 100 (-18 to 38)