Troubleshooting - Mitsubishi Electric MSC-A07YV-E1 Service Manual

Wireless type
Table of Contents

Advertisement

10

TROUBLESHOOTING

MSC-A07YV -
E1
MSC-A09YV -
E1
MSC-A12YV -
E1
10-1. Cautions on troubleshooting
1. Before troubleshooting, check the following:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
2. Take care the following during servicing.
1) Before servicing the air conditioner, be sure to first turn off the remote controller to stop the unit, and then after con-
firming the horizontal vane is closed, turn off the breaker and/or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic
control P.C. board.
3) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the
components.
4) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
3. Troubleshooting procedure
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the
components for bursting and discoloration.
3) When troubleshooting, refer to the flow chart on page 20 and the check table on page 21.
4. How to replace batteries
Weak batteries may cause the remote controller malfunction.
In this case, replace the batteries to operate the remote controller normally.
1 Remove the front lid and insert batteries.
Then reattach the front lid.
NOTE1 : If the RESET button is not pressed, the remote controller may not operate correctly.
NOTE2 : INFORMATION FOR MULTI SYSTEM AIR CONDITIONER
(OUTDOOR UNIT : MXZ-A18WV-
Multi system air conditioner (Outdoor unit MXZ-A18WV-
more indoor units with one outdoor unit.
According to the capacity, two or more units can operate simultaneously.
•When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and the
other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units that
will start the operation later cannot operate, indicating as shown in the figure below. In this case, please set all the
indoor units to the same operation mode.
•When indoor units starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes
(max. 10 minutes) to blow out the warm air.
•In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flowing
may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
Housing point
Lead wiring
Insert the negative pole
of the batteries first.
Check if the polarity of
the batteries are correct.
MXZ-A26WV-
E1
2 Press the RESET button.
RESET button
MXZ-A32WV-
E1
E1
MXZ-A26WV-
E1
E1
Operation Indicator
19
)
MXZ-A32WV-
) can connect two or
E1
lighted
flashing

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc-a12yv-e1Msc-a09yv-e1Msc-a07yvMsc-a09yvMsc-a12yv

Table of Contents