4. How to Start-up the Test Mode
Specifications for Operation
A
Operation method
SOURCE + CLOCK/TA + RESET
<Demonstration screen>
L O O P
B
Select Mode by right & left keys. Select LOCAL TX NM (data non-modulation).
L O C A L
Determine by Center key and select frequency. Initial value is 2 402 MHz.
Select frequency by Up & Down keys. Initial value is 2 402 MHz.
02:2402<->41:2441<->80:2480
C
T X
F L E Q
Determine by Center key.
Screen displaying LOCAL TX NM Setup Defined. This is the end of product setup.
D
Center key
L O C A L
DISP key
T 0 2
Measure each of 02, 41 and 80.
Return to SEL screen by BAND key.
E
F
36
1
2
P I O N E E R
PHONE
B A C K
T X
N M
0 2 - 2 4 0 2
T X
N M
E X E
R - -
G - -
E X E
FH-P800BT/XJ/UC
2
3
Determine the output level of each frequency
by spectrum analyzer upon the above connection.
The output level V must be within the range
of the following as a determination standard:
"-6 dBm<V<4 dBm"